| Plan Review Notes For Permit 22100154 |
| Permit Number |
22100154 |
|
| Review Stop |
B |
| Sequence Number |
5 |
|
| Notes |
| Date |
Text |
| 2023-04-21 11:56:09 | NEW SFR | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | COMMENTS ARE FOR PLANS FOR 22100154 AND 23021456 | | | | | | 1) DRAWING A-4.0 THE CABANA SHOWS A FOAM INSULATION - | | | PLEASE PROVIDE THE TEST REPORTS (ICC EVALUATION REPORT) | | | FOR THE FOAM SPRAY INSULATION FBC R316.3 SURFACE | | | BURNING CHARACTERISTICS. | | | UNLESS OTHERWISE ALLOWED IN SECTION R316.5, FOAM | | | PLASTIC OR FOAM PLASTIC CORES USED AS A COMPONENT IN | | | MANUFACTURED ASSEMBLIES USED IN BUILDING CONSTRUCTION | | | SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 75 AND | | | SHALL HAVE A SMOKE-DEVELOPED INDEX OF NOT MORE THAN 450 | | | WHEN TESTED IN THE MAXIMUM THICKNESS AND DENSITY | | | INTENDED FOR USE IN ACCORDANCE WITH ASTM E84 OR UL 723. | | | | | | 2) THE PROVIDED ENERGY CALCS. (FORM R405) WILL NEED TO | | | BE REVISED FOR THE CABANA - INSULATION AT THE CEILING | | | AND ATTIC VENTING DOES NOT MATCH THE DRAWINGS FOR THE | | | CABANA. | | | | | | 3) DRAWINGS S3.01, A-5.0, A-4.0 DO NOT SHOW AS | | | DIGITALLY SIGNED IN ADOBE READER - SIGNED AND SEALED | | | DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). |
|