Plan Review Notes
Plan Review Notes For Permit 22091110
Permit Number 22091110
Review Stop B
Sequence Number 1
Notes
Date Text
2022-12-12 13:53:22NEW SFR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) PRODUCT APPROVALS LISTED ON
 THE DRAWINGS.
  
 2) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVALS FOR THE ROOFING TILE - PLEASE CIRCLE
 THE TILE ATTACHMENT TYPE IN THE PRODUCT APPROVAL - IF
 USING ADHESIVE TO ATTACH THE TILE PROVIDE THE PRODUCT
 APPROVAL FOR THE ADHESIVE.
  
 3) PLEASE SHOW THE ATTIC ACCESS OPENING SIZE ( 22" X
 30" ) - FBC R807.1 ATTIC ACCESS.
 BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF CONSTRUCTION
 SHALL HAVE AN ATTIC ACCESS OPENING TO ATTIC AREAS THAT
 HAVE A VERTICAL HEIGHT OF 30 INCHES (762 MM) OR GREATER
 OVER AN AREA OF NOT LESS THAN 30 SQUARE FEET (2.8 M2).
 THE VERTICAL HEIGHT SHALL BE MEASURED FROM THE TOP OF
 THE CEILING FRAMING MEMBERS TO THE UNDERSIDE OF THE
 ROOF FRAMING MEMBERS. THE ROUGH-FRAMED OPENING SHALL BE
 NOT LESS THAN 22 INCHES BY 30 INCHES (559 MM BY 762 MM)
 AND SHALL BE LOCATED IN A HALLWAY OR OTHER LOCATION
 WITH READY ACCESS.
  
 4) PLEASE SHOW THE GARAGE FLOOR TO SLOPE - FBC R309.1
 THE AREA OF FLOOR USED FOR PARKING OF AUTOMOBILES OR
 OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE
 MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE MAIN
 VEHICLE ENTRY DOORWAY.
  
 5) THE WIND DESIGN IS SHOWN USING EXPOSURE "C". WITH
 THE LOCATION OF THE PROPERTY LOCATED ON THE LARGE LAKE
 EXPOSURE "D" SHOULD BE USED FOR THE WIND DESIGN. FBC
 R301.2.1.4.3 EXPOSURE D SHALL APPLY WHERE THE GROUND
 SURFACE ROUGHNESS, AS DEFINED BY SURFACE ROUGHNESS D,
 PREVAILS IN THE UPWIND DIRECTION FOR A DISTANCE OF AT
 LEAST 5,000 FEET (1524 M) OR 20 TIMES THE HEIGHT OF THE
 BUILDING, WHICHEVER IS GREATER.
  
 6) THE SIGNED AND SEALED SOIL REPORT PROVIDED DOES NOT
 SHOW AS DIGITALLY SIGNED IN ADOBE READER. SIGNED AND
 SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  