Notes
Date Text
2022-09-19 11:50:01WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. REVISION: 22090583
 W. P. B. PERMIT: 22021141
 ADD: 4 HARVARD CIRCLE
 CONT: VERTEX
 TEL: 561-619-7722
 E-MAIL: [email protected]
  
 1) LIFE SAFETY SHEET SHOWS OCCUPANT LOAD FOR BUILDING
 AT 16 PERSONS BUT NOT THE PLUMBING OCCUPANT LOAD PER
 2020 FBC-BUILDING TABLE 2902.1. THE OCCUPANT LOAD
 FACTOR IS STILL 100 NOT THE 150 OF THE BUILDING CODE
 MAKING THE PLUMBING OCCUPANT LOAD 24 PERSONS. SEE
 SECTION 2902.6 OCCUPANT LOADS 15 OR LESS DO NOT NEED TO
 MEET THE DRINKING FOUNTAIN REQUIREMENTS BUT OVER 15
 OCCUPANTS NEED TO SHOW COMPLIANCE WITH:
 1A) 2020 FBC-ACCESSIBILITY CODE. 211.2 MINIMUM NUMBER.
 NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED.
 ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH
 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH
 602.7.
  
 1B) PROTRUDING OBJECTS 307.2 PROTRUSION LIMITS 307.2.
 OBJECTS WITH LEADING EDGES MORE THAN 27 INCHES AND NOT
 MORE THAN 80 INCHES ABOVE THE FLOOR SHALL NOT PROTRUDE
 MORE THAN 4 INCHES HORIZONTALLY INTO THE CIRCULATION
 PATH.
  
 1C) 602.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE
 COMPLYING WITH 305, POSITIONED FOR A FORWARD APPROACH,
 AND KNEE AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE
 PROVIDED.
  
 1D) SPOUT OUTLETS/ DRINKING FOUNTAINS. 2017 ACCESS.
 CODE. SPOUT OUTLETS SHALL COMPLY WITH:
 1D)(1) 602.4 SPOUT HEIGHT. 36 INCHES MAXIMUM ABOVE THE
 FINISH FLOOR OR GROUND FOR WHEELCHAIR BOUND
 INDIVIDUALS.
 1D)(2) 602.7 SPOUT HEIGHT FOR THE STANDING PERSONS
 SHALL BE BETWEEN 38 TO 43 INCHES ABOVE FINISH FLOOR.
  
 2) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved