Text |
| 2022-10-07 16:25:57 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SUBMIT SIGNED AND SEALED ENGINEERING FOR WINDLOADS | | | ON THE FLAG POLE TO SHOW IT WILL CAN WITHSTAND THE | | | LOADS. THE EXPOSURE CATEGORY IS C AND THE ULTIMATE WIND | | | SPEED FOR RISK CATEGORY I STRUCTURES IS 155 MPH AT THIS | | | LOCATION. FBC 1609.3 |
|