2022-10-12 15:08:092ND PLUMBING REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 THE CURRENT DOCUMENTS WERE SUBMITTED BEFORE THE
 PLUMBING REVIEW, AND NO NEW PAGES HAVE BEEN SUBMITTED
 SINCE THE FAILED REVIEW.
  
 1) ----NO CHANGES SINCE 1ST REVIEW---- SHEETS P-1, P-2,
 P-3: THE PLANS INDICATE THE EXISTING GARAGE AND
 ATTACHED SEMI-FINISHED BASE AREA WILL BE REMODELED AND
 CONVERTED INTO A DWELLING UNIT. A SEPARATE PERMIT WILL
 REQUIRED FOR THE PROPOSED WORK- SECS. 105.1& 107.2.1
 WPB.
  
 2) ----NO CHANGES SINCE 1ST REVIEW---- P1, P2, & P3:
 TWO DWELLINGS ON THE SAME LOT WILL REQUIRE WATER USERS
 TO INSTALL A BACKFLOW PREVENTION ASSEMBLY AT THE POINT
 OF DELIVERY. A REDUCED PRESSURE ZONE BACKFLOW DEVICE
 WILL BE REQUIRED FOR THE WATER METER PER THE CITY OF
 WEST PALM CROSS UTILITIES DEPARTMENT AND THEIR
 CONNECTION CONTROL PROGRAM.
 PLEASE NOTE THAT A FL. LICENSED PLUMBING CONTRACTOR
 SHALL OBTAIN A SEPARATE PERMIT FOR INSTALLATION OF THE
 BACKFLOW PREVENTER IN ACCORDANCE WITH SECTION 105.1 WPB
 AND SEC. 90-33 WPB CODE OF ORDINANCES. THE DEVICE SHALL
 BE TESTED AND CERTIFIED BY THE WPB UTILITIES DEPARTMENT
 PRIOR TO FINAL INSPECTION BY THE BUILDING DEPARTMENT.
 PLEASE CONTACT THE WPB UTILITIES CENTRAL OPERATIONS
 DEPT.AT 561-822-2210 FOR FURTHER INFORMATION.
  
 3) ----NO CHANGES SINCE 1ST REVIEW---- P-1: THE WATER
 PIPE LEGEND NOTE #3 SPECIFYING A 1/2-INCH MAIN HW LINE
 APPEARS TO BE INCORRECT AND SHOULD INDICATE 3/4-INCH
 FOR THE WSFU DEMAND- P2903.6 & P2903.7 FBC RES.
  
 5) ----NO CHANGES SINCE 1ST REVIEW---- P-1, P-2: THE
 DRAWINGS SHOW A WATER LINE TO A BBQ SINK BUT NO DRAIN
 AND VENT PIPING- SEC. P2601.2 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR