| Plan Review Notes For Permit 22081229 |
| Permit Number |
22081229 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2022-09-21 15:12:06 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC R 4501.17, IT APPEARS THAT THIS FENCE IS PART OF A | | | POOL BARRIER. PLEASE PROVIDE ALL GATE LOCATIONS ON | | | SURVEY SHOWING COMPLIANCE WITH THIS CODE SECTION | | | INCLUDING: | | | | | | FBC R 4501.17.1.8, PLEASE SHOW GATE AND GATE LOCKING | | | DEVICE DETAILS. THE GATES MUST HAVE A SELF LATCHING | | | LOCKING DEVICE LOCATED NO LESS THAN 54" FROM BOTTOM OF | | | GATE OR PER ALTERNATE CODE REQUIREMENTS. THE GATES MUST | | | OPEN OUTWARD AWAY FROM POOL. THE GATES AND BARRIER MUST | | | HAVE NO OPENING GREATER THAN 1/2" WITHIN 18" OF THE | | | RELEASE MECHANISM. | | | | | | FBC R 45017.1.9, PLEASE SHOW ON SURVEY THE LOCATION OF | | | WINDOWS AND DOORS THAT PROVIDE ACCESS TO THE POOL AREA. | | | THESE OPENINGS MUST HAVE ALARMS OR ALTERNATE ALARM | | | METHOD PER THIS CODE SECTION. |
|