| 2022-12-15 17:00:43 | 1) BAMBOO PROPOSED IS SPECIFIED AT 18-20 FT IN HEIGHT. |
| | AS PREVIOUSLY STATED, HEDGES ON PERIMETER CANNOT EXCEED |
| | 10 FT PER CODE (BAMBOO PROPOSED). PLEASE CHANGE |
| | MATERIAL OR SPECS. |
| | |
| | 2) PER SEC 94-482 (A) THE LESSER OF 1000 SQ FT OR 75 |
| | PERCENT OF THE FRONT YARD AREA SHALL BE LANDSCAPED WITH |
| | LIVING PLANT MATERIAL. PLANS PROVIDED DO NOT MEET THIS |
| | REQUIREMENT. |
| | |
| | 3) PLEASE CORRECT DESIGN OPTIONS CHART. ONLY ONE |
| | CATEGORY FOR DROUGHT AND ONE FOR NATIVE MAY BE SELECTED |
| | FOR EACH SECTION (GROUNDCOVER, TREES, SHRUBS). TREES, |
| | GROUNDCOVER, OR SHRUBS COUNTED FOR NATIVE CANNOT BE |
| | COUNTED FOR DROUGHT TOLERANCE AND VICE VERSE FOR |
| | CREDIT. |
| | |
| | 4) PLEASE PROVIDE OPEN SPACE CALCULATIONS ON PLANS. |
| | THIS VERSION OF PLANS DOES NOT HAVE THEM. |
| | |
| | 5) DROUGHT TOLERANT MATERIAL LISTED IN DESIGN OPTIONS |
| | CHART MUST BE LISTED AS HAVING LOW WATERING NEEDS (NOT |
| | MEDIUM OR HIGH) ACCORDING TO WATERWISE, THE SOUTH |
| | FLORIDA WATER MANAGEMENT DISTRICT PLANT AND LANDSCAPE |
| | GUIDE. BAMBOO IS NOT DROUGHT TOLERANT. FICUS RUBIGNOSA |
| | IS NOT NATIVE. MOREOVER THERE IS ONLY ONE PROPOSED |
| | COMPARED TO THE 7 REQUIRED TREES FOR THE LOT. THIS IS |
| | NOT 51 PERCENT OR GREATER OR 25 PERCENT OF REQUIRED |
| | TREES. IF CHRISTMAS PALMS ARE SUBSTITUTED FOR TREES |
| | THEY ARE TO BE DONE SO ON A 3:1 BASIS. THE THREE |
| | CHRISTMAS PALMS MAKE UP 1 REQUIRED TREE. THIS IS NOT 51 |
| | PERCENT OF REQUIRED TREES OR 25 PERCENT. PLEASE CORRECT |
| | ALL DISCREPANCIES INCLUDING THOSE NOT MENTIONED HERE ON |
| | DESIGN OPTIONS CHART. |
| | |
| | SMITH AMISIAL |
| | [email protected] |
| | |