| Date |
Text |
| 2023-01-13 12:18:58 | 3RD NFIP REVIEW |
| | RESULTS: CORRECTIONS NEEDED |
| | |
| | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM |
| | PLANS EXAMINER II |
| | CITY OF WEST PALM BEACH |
| | (561) 805-6726 |
| | [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | CITY ORDINANCE NO. 4658-16 AND NO. 4729-17 |
| | FEMA DESK REFERENCE P 758 |
| | FBC R322 FLOOD-RESISTANT CONSTRUCTION |
| | |
| | |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | DETACHED GARAGE. FLOOD ZONE AE 7. DESIGN FLOOD |
| | ELEVATION 9'0"NAVD. |
| | |
| | |
| | 1. A VALID DIGITAL SIGNATURE IS REQUIRED ON THE |
| | ELEVATION CERTIFICATE. |
| | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS |
| | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE |
| | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO |
| | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. |
| | 481, F.S. & 61G1. |
| | |
| | 2. LINE A8A) SHOULD BE THE TOTAL SQUARE FOOTAGE OF THE |
| | GARAGE AND STORAGE AREA. THIS IS 1009SF. SEE |
| | CALCULATION UNDER BLDG REVIEW. |
| | |
| | 3. LINE C2D) SHOULD BE N/A. THIS IS A DETACHED GARAGE |
| | ACCESSORY STRUCTURE. |
| | |
| | 4. LINE C2E) DATA MISSING. STATE THE ELEVATION OF THE |
| | BOTTOM OF THE WALL MOUNTED A/C CU. MINIMUM OF 9'0"NAVD. |
| | |
| | 5. LINE C2F) SHOULD BE 3.36'. |
| | |
| | 6. LINE C2G) SHOULD BE 4.92'. |
| | |
| | 7. REFERENCE SECTION D COMMENTS FOR THE FOLLOWING: |
| | 7A. MACHINERY SHOULD BE THE WALL MOUNTED A/C CU. |
| | 7B. THERE ARE ONLY 5 SMART VENTS INSTALLED. SEE LINE |
| | A8B OF EC. |
| | 7C. ADD COMMENT FROM THE EC INSTRUCTIONS AS FOLLOWS: |
| | THE INTERIOR GARAGE FLOOR IS USED FOR THE SMART VENT |
| | INSTALLED IN THE INTERIOR PARTITION. |
| | EC INSTRUCTIONS: ITEM A8.B-D. ENTER IN ITEM A8.B THE |
| | NUMBER OF PERMAMENT FLOOD OPENINGS IN THE CRAWLSPACE OR |
| | ENCLOSURE(S) THAT ARE NO HIGHER THAN 1.0 FOOT ABOVE THE |
| | HIGHER OF THE EXTERIOR OR INTERIOR GRADE OR FLOOR |
| | IMMEDIATELY BELOW THE OPENING. (A PERMAMENT FLOOD |
| | OPENING IS A FLOOD VENT OR OTHER OPENING THAT ALLOWS |
| | THE FREE PASSGAE OF WATER AUTOMATICALLY IN BOTH |
| | DIRECTIONS WITHOUT HUMAN INTERVENTION.) IF THE INTERIOR |
| | GRADE ELEVATION IS USED, NOTE THIS IN THE COMMENTS AREA |
| | OF SECTION D. |
| | |
| | NOTICE: THE FOLLOWING (2) ELEVATION CERTIFICATES ARE |
| | REQUIRED. |
| | |
| | A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS |
| | REQUIRED AT PLACEMENT OF 1ST FLOOR. |
| | |
| | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS |
| | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL |
| | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |