| Date |
Text |
| 2022-12-07 16:51:06 | RENOVATION |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| | AMENDMENT |
| | |
| | CORRECTIONS NEEDED - |
| | |
| | 1) THE PRODUCT APPROVALS FOR THE 8000 ALUMINUM WINDOW |
| | WALL AND THE PIVOT DOOR ARE NOT COMPLETE (FRONT PAGES |
| | AND THE INSTALLATION INSTRUCTIONS) - PLEASE PROVIDE |
| | COMPLETE (FRONT PAGES AND THE INSTALLATION |
| | INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE PRODUCT |
| | APPROVALS FOR THE EXTERIOR WINDOWS AND DOORS. ALL |
| | PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED |
| | APPROVED BY THE DESIGNER OF RECORD OR BE SHOWN ON THE |
| | PLANS BY PRODUCT APPROVAL NUMBER _ FBC WPB 107.3.4 |
| | |
| | 2) PLEASE SHOW THE WIND DESIGN DATA USED FOR WIND |
| | DESIGN PER FBC 1603.1.4 |
| | |
| | 3) PIVOT DOOR PRODUCT APPROVAL SEE PAGE 3 OF 11 (NOTE: |
| | DOOR CANNOT BE USED AS AN EGRESS DOOR WHEN THE DOOR |
| | LEAF WIDTH IS MORE THAN 48") -- THE 6 FOOT WIDE ENTRY |
| | DOOR SHOWN DOES NOT COMPLY WITH FBC 1010.1.1 SIZE OF |
| | DOORS. THE MAXIMUM WIDTH OF A SWINGING DOOR LEAF SHALL |
| | BE 48 INCHES (1219 MM) NOMINAL |
| | |
| | 4) PLEASE SHOW THE MAIN "USE" FOR EACH BUILDING ( |
| | RESTAURANT, PROFESSIONAL OFFICES, STORAGE (WHAT |
| | MATERIALS OF STORAGE), RETAIL OR WHOLESALE STORE ETC.) |
| | - A WAREHOUSE WOULD BE A STORAGE AREA PLEASE SEE FBC |
| | SECTION 311 AND SHOW THE OCCUPANCY CLASSIFICATION AS S1 |
| | OR S2 - THE OCCUPANCY CLASSIFICATION NEEDS TO BE |
| | DETERMINED - FBC 302.1 OCCUPANCY CLASSIFICATION. |
| | OCCUPANCY CLASSIFICATION IS THE FORMAL DESIGNATION OF |
| | THE PRIMARY PURPOSE OF THE BUILDING, STRUCTURE OR |
| | PORTION THEREOF. STRUCTURES SHALL BE CLASSIFIED INTO |
| | ONE OR MORE OF THE OCCUPANCY GROUPS LISTED IN THIS |
| | SECTION BASED ON THE NATURE OF THE HAZARDS AND RISKS TO |
| | BUILDING OCCUPANTS GENERALLY ASSOCIATED WITH THE |
| | INTENDED PURPOSE OF THE BUILDING OR STRUCTURE. |
| | |
| | |