| Date |
Text |
| 2023-02-24 15:22:03 | 2ND REVIEW FMC |
| | PERMIT: 22080569 |
| | |
| | CODES IN EFFECT: 2020 |
| | |
| | FBC- FLORIDA BUILDING CODE |
| | FMC- FLORIDA MECHANICAL CODE |
| | FEC- FLORIDA ENERGY CONSERVATION |
| | FGC- FLORIDA FUEL GAS |
| | FEX- FLORIDA EXISTING BUILDING CODE |
| | FRC- FLORIDA RESIDENTIAL BUILDING CODE |
| | F.S.- FLORIDA STATUTES |
| | FAC- FLORIDA ACCESSIBILITY CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | THERE WERE SEVERAL SHEETS SUBMITTED THAT WERE NOT ON |
| | THE NARRATIVE. BELOW IS A LIST OF COMMENTS. |
| | |
| | 1) SHEET M.208A: EXPLAIN EG-10 IN WHAT WAS THE TENNIS |
| | STORAGE AREA. |
| | |
| | 2) SHEET M.208A: EXPLAIN THE AREA WHERE THE NEW VAV-7 |
| | IS CONDITIONING. ALSO PROVIDE THE EQUIPMENT SIZING |
| | CALCULATIONS AND OUTDOOR AIR CALCULATIONS FOR THIS |
| | SPACE. FEC C402 : FEC C403.2.1 |
| | |
| | 3) SHEET M.208B: PROVIDE THE ENERGY CALCULATIONS FOR |
| | THE NEW KITCHEN AND DINING SPACES. FEC C402 |
| | |
| | 4) ADD A NOTE TO THESE DRAWINGS STATING THAT THE |
| | KITCHEN HOOD AND GREASE DUCT WILL REQUIRE A SEPARATE |
| | PERMIT, DOCUMENT SUBMITTAL AND PLAN REVIEW AS THEY WILL |
| | NOT BE REVIEWED UNDER THIS REVISION. |
| | |
| | 5) ADD A NOTE TO THESE DRAWINGS STATING THAT THE |
| | WALK-IN COOLER WILL REQUIRE A SEPARATE PERMIT, DOCUMENT |
| | SUBMITTAL AND PLAN REVIEW AS THEY WILL NOT BE REVIEWED |
| | UNDER THIS REVISION. |
| | |
| | 6) SHOW HOW THE NEW HOTEL ROOMS MECHANICAL SYSTEMS |
| | MEET THE ENERGY REQUIREMENTS OF FEC C403.2.4.8 |
| | |
| | 7) SHEET M.252: NEW ENLARGED ROOMS: THE CLOUDED |
| | DRAWINGS REFERENCE NOTES 5, 6 AND 8 BUT NOTES 5, 6 AND |
| | 8 ARE NOT ON THE DRAWINGS. INCLUDE THE NOTES ON THE |
| | DRAWINGS. THESE NEW ENLARGED ROOMS WILL REQUIRE |
| | MECHANICAL EQUIPMENT SIZING CALCULATIONS. FBC 107.3.5 |
| | AND FEC C403.2.1 |
| | |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM. |
| | |
| | MICHAEL EDWARDS |
| | MECHANICAL EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL. 33401 |
| | 561-805-6728 |
| | [email protected] |
| | |