| Plan Review Notes For Permit 22080415 |
| Permit Number |
22080415 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2022-10-03 09:08:10 | JAMES P. BAKER | | | ASSISTANT BUILDING OFFICIAL | | | [email protected] | | | 561-805-6710 | | | | | | FBC=FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | | | | | | | 1. FBC B 1609, PROVIDE A STRUCTURAL DETAIL TO SHOW HOW | | | THE CHANNEL LETTERS WILL BE CONSTRUCTED AND HOW THEY | | | WILL BE FASTENED TO THE EXISTING MONUMENT SIGN AND THE | | | EXISTING PYLON SIGN. THIS STRUCTURAL DETAIL SHOULD SHOW | | | SIGN CONSTRUCTION, SUBSTRATE, WIND DESIGN CRITERIA, | | | FASTENERS INCLUDING FASTENING PATTERN, FASTENER TYPE, | | | DIAMETER, MINIMUM EMBEDMENT. | | | | | | 2. FS 471, ENGINEERING IS REQUIRED. | | | |
|