| 2023-01-11 14:44:32 | RESIDENTIAL (R3) THIRD BUILDING REVIEW COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #22080253 |
| | 8403 IRONHORSE CT. |
| | |
| | (1)- ARMOR SCREEN ROLL-UP SHUTTERS: |
| | |
| | PREVIOUS COMMENT: |
| | A) SHUTTERS INSTALLATION SCHEDULE SPECIFY CONCRETE AS |
| | THE SUBSTRATE WHERE SHUTTERS ARE GOING TO BE INSTALLED. |
| | ACCORDING TO CITY RECORDS, THE COLUMNS SUPPORTING THE |
| | ROLL-UP SHUTTERS ARE NOT CONCRETE. THEY ARE FILLED |
| | CONCRETE BLOCK COLUMNS. REVISE SHUTTERS INSTALLATION |
| | SCHEDULE TO REFLECT CORRECT SUBSTRATE. SEC. 107.2.1 |
| | CITY AMENDMENTS. SEC. R301.2.1 FBC-RESIDENTIAL. |
| | |
| | RESPONSE: |
| | REVISE ARMOR SCREEN INSTALLATION SCHEDULE: |
| | 1-INFORMATION ON TOP OF FORM IS INCORRECT. INFORMATION |
| | IS FOR ARMOR SCREEN CORPORATION NOT FOR FOLDING SHUTTER |
| | CORPORATION.REVISE AS REQUIRED TO MATCH , INCLUDING |
| | PRODUCT APPROVAL NUMBER. |
| | SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | 2-IT IS NOT CLEAR WHICH ANCHOR IS GOING TO BE USED. TOP |
| | OF FORM SPECIFIES 1/4" CRETE FLEX, WHILE INSTALLATION |
| | SCHEDULE SPECIFIES 1/4" TAPCON. REVISE AS REQUIRED AND |
| | CLEARLY MARK ARMOR SCREEN CORPORATION PRODUCT APPROVAL |
| | UNDER THE SOLID GOUTED ACMU TABLE ON SHEET 10 OF 12 TO |
| | AVOID CONFLICTS/DELAYS. |
| | SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | 2- ACCORDING SHUTTERS: |
| | |
| | PREVIOUS COMMENT: |
| | A) SHUTTERS INSTALLATION SCHEDULE SPECIFY CONCRETE AS |
| | THE SUBSTRATE WHERE SHUTTERS ARE GOING TO BE INSTALLED |
| | (TOP AND BOTTOM). TYPICALLY THE BOTTOM OF WINDOW |
| | OPENINGS IS CONCRETE BLOCK. REVISE INSTALLATION |
| | SCHEDULE USING THE ANCHOR FOR CONCRETE BLOCK SUBSTRATE |
| | AT THE BOTTOM OR PROVIDE PROOF SHOWING BOTTOM OF |
| | OPENINGS HAS POURED CONCRETE WITH THE STRENGTH |
| | SPECIFIED ON ANCHOR SCHEDULE OF PRODUCT APPROVAL |
| | SUBMITTED. |
| | SEC. 107.2.1 CITY AMENDMENTS. SEC. R301.1 |
| | FBC-RESIDENTIAL. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | PREVIOUS COMMENT: |
| | B) REVISE SHUTTER GLASS SEPARATION SPECIFIED ON SHUTTER |
| | INSTALLATION SCHEDULE FOR OPENINGS WITH A SHUTTER SPAN |
| | LONGER THAN 99 INCHES. SEE SHEET 13 OF 13 OF SHUTTERS |
| | PRODUCT APPROVAL AND REVISE AS REQUIRED. NEED 3-1/2 |
| | INCH GLASS SEPARATION. |
| | SEC. 107.2.1 CITY AMENDMENTS. SEC. R301.1 |
| | FBC-RESIDENTIAL. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND |
| | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE |
| | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |
| | |