| 2022-09-16 11:34:21 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) ON SHEET A1.2 LIFE SAFETY PLAN THE COMMON PATH OF | | | TRAVEL IS SPECIFIED AS 166 FT. FBC 1006.2.1 REQUIRES | | | TWO EXITS WHEN THE COMMON PATH OF TRAVEL IS MORE THAN | | | 100 FT. | | | | | | 2) THE OCCUPANT LOAD CALCULATIONS ON THE PLANS HAS | | | FRACTIONS WHICH ARE REQUIRED TO BE ROUNDED UP BECAUSE | | | YOU CAN NOT HAVE A FRACTION OF PEOPLE. IF YOU ROUND UP | | | THE NUMBERS IN THE CHART YOU WILL HAVE A TOTAL OCCUPANT | | | LOAD OF 52 (3+29+1+1+18=52). FBC 1006.2.1 REQUIRES TWO | | | EXISTS FROM THE SPACE IF THE OCCUPANT LOAD EXCEEDS 49 | | | PEOPLE. | | | | | | 3) SHOW COMPLIANCE WITH FBC 1007.1.1 EXCEPTION (2) | | | REQUIRES THE TWO EXITS TO BE SEPARATED BY NOT LESS THAN | | | ONE-THIRD THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL | | | DIMENSION OF THE AREA SERVED. | | | | | | 4) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH | | | OF THE REVIEW COMMENTS HAS BEEN ADDRESSED | | | |
|