| Date |
Text |
| 2022-08-31 14:19:54 | FLORIDA BUILDING CODE 2020 7TH EDITION |
| | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED |
| | NFPA 70 2017 EDITION |
| | |
| | JAKE LEAHY |
| | ELECTRICAL PLANS EXAMINER II |
| | 561-805-6713 |
| | [email protected] |
| | |
| | 1) NO SMOKE DETECTORS SHOWN. R314 FBC 2020 |
| | |
| | 2) SERVICE SHOWS 2/0 FOR FEEDERS GOING TO THE PANELS. |
| | DOES NOT MEET 310.15 (B)(7)(2) |
| | |
| | 310.15.(B)(7) |
| | FOR A FEEDER RATED 100 THROUGH 400 AMPERES, THE FEEDER |
| | CONDUCTORS SUPPLYING THE ENTIRE LOAD ASSOCIATED WITH A |
| | ONE-FAMILY |
| | DWELLING, OR THE FEEDER CONDUCTORS SUPPLYING THE ENTIRE |
| | LOAD ASSOCIATED WITH AN INDIVIDUAL DWELLING UNIT IN A |
| | TWO-FAMILY OR |
| | MULTIFAMILY DWELLING, SHALL BE PERMITTED TO HAVE AN |
| | AMPACITY NOT LESS THAN 83 PERCENT OF THE FEEDER RATING. |
| | |
| | 3) MASTER BATH OUTLETS MAY BE TO CLOSE TO THE SHOWER |
| | AND TUB. 210.8(A)(9) |
| | |
| | 210.8(A)(9) BATHTUBS OR SHOWER STALLS ? WHERE |
| | RECEPTACLES ARE INSTAL?LED WITHIN 1.8 M (6 FT) OF THE |
| | OUTSIDE EDGE OF THE |
| | BATHTUB OR SHOWER STALL |
| | |
| | 4) OUTLETS REQUIRED AT THE FRONT AND REAR OF RESIDENCE |
| | 210/52(E)(1) |
| | |
| | FOR A ONE-FAMILY DWELLING AND EACH UNIT OF A TWO-FAMILY |
| | DWELLING THAT IS AT GRADE LEVEL, AT LEAST ONE |
| | RECEPTACLE OUTLET |
| | READILY ACCESSIBLE FROM GRADE AND NOT MORE THAN 2.0 M |
| | (6 1?2 FT) ABOVE GRADE LEVEL SHALL BE INSTALLED AT THE |
| | FRONT AND |
| | BACK OF THE DWELLING. |
| | |
| | 5) OUTLETS ARE REQUIRED IN THE GARAGE ONE FOR EACH |
| | SPACE. 210.52 |
| | |
| | IN EACH ATTACHED GARAGE AND IN EACH DETACHED GARAGE |
| | WITH ELECTRIC POWER, AT LEAST ONE RECEPTACLE OUTLET |
| | SHALL BE |
| | INSTALLED IN EACH VEHICLE BAY AND NOT MORE THAN 1.7 M |
| | (51?2 FT) ABOVE THE FLOOR. |
| | |
| | 6) BALCONIES REQUIRE OUTLETS TO BE INSTALLED |
| | 210.52(E)(3) |
| | |
| | BALCONIES, DECKS, AND PORCHES THAT ARE ATTACHED TO THE |
| | DWELLING UNIT AND ARE ACCESSIBLE FROM INSIDE THE |
| | DWELLING |
| | UNIT SHALL HAVE AT LEAST ONE RECEPTACLE OUTLET |
| | ACCESSIBLE FROM THE BALCONY, DECK, OR PORCH. THE |
| | RECEPTACLE OUTLET |
| | SHALL NOT BE LOCATED MORE THAN 2.0 M (61?2 FT) ABOVE |
| | THE BALCONY, DECK, OR PORCH WALKING SURFACE. |