Plan Review Notes
Plan Review Notes For Permit 22080091
Permit Number 22080091
Review Stop NFIP
Sequence Number 1
Notes
Date Text
2022-08-18 09:24:12NFIP PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16 AND NO. 4729-17
 FBC R322 FLOOD-RESISTANT CONSTRUCTION
  
 1ST REVIEW
  
 FINISHED CONSTRUCTION ELEVATION CERTIFICATE
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
  
 NOTICE: THIS PROJECT IS LOCATED IN A SPECIAL FLOOD
 HAZARD AREA (SFHA). THE FLOOD ZONE DESIGNATION FOR THIS
 SITE IS AE WITH A BASE FLOOD ELEVATION (BFE) OF 7'-0"
 NAVD.
 THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO.
 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD.
 THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE
 9'-0" NAVD.
  
 CITY OF WEST PALM BEACH, FLORIDA ORDINANCE NO. 4729-17
 SECTION 4: THE CODE OF ORDINANCES IS HEREBY AMENDED AT
 CHAPTER 18, BUILDINGS AND BUILDING REGULATIONS, ARTICLE
 II, BUILDING CODE, TO ADD SECTION 18-33, TECHNICAL
 AMENDMENTS TO FLORIDA BUILDING CODE, RESIDENTIAL, WHICH
 SHALL READ AS FOLLOWS:
  
 SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA BUILDING
 CODE, RESIDENTIAL.
 R322.2.1 ELEVATION REQUIREMENTS.
 1. BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT
 DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST
 FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION
 PLUS TWO FEET OR THE DESIGN FLOOD ELEVATION, WHICHEVER
 IS HIGHER.
 SEC. 18-34 - TECHNICAL AMENDMENTS TO FLORIDA BUILDING
 CODE, BUILDING.
  
 NOTICE: PRODUCT APPROVALS AND ICC-ES REPORT FOR SMART
 VENTS REVIEWED AND APPROVED UNDER MASTER PERMIT
 20090239.
  
 1. PROVIDE A FINAL BOUNDARY LINE SURVEY. INCLUDE THE
 FINISHED FLOOR ELEVATION OF THE MAIN DWELLING UNIT AND
 GARAGE.
  
 2. LINE A1. OWNER OF RECORD PER PBC PROPERTY APPRAISERS
 OFFICE AND PBC GIS IS SOUTHEAST LAND DEVELOPMENT AND
 CONSTRUCTION LLC.
  
 3. LINE A6. PROVIDE PHOTOS OF EACH LOCATION WITH FLOOD
 OPENINGS.
  
 4. LINE A9A). EC STATES GARAGE IS 466 SF. PLAN PAGE
 SP-1.01 STATES GARAGE IS 519SF. PLEASE CLAIFY. REVISION
 TO PLAN PAGE SP-1.01 MAY BE REQUIRED.
  
 5. LINE A9B). (SEE # 8 BELOW) IF GARAGE TOP OF SLAB
 (TOS) IS 8'-0" AS SHOWN ON PLAN PAGES A-1.01 AND A-3.02
 THEN THE TOP 4 INCHES OF THE 16 X 16 VENTS WILL NOT
 CONTRIBUTE TO THE NET AREA OF A9C). PLEASE REVIEW AND
 CORRECT AS NECESSARY.
  
 6. LINE B8. PER PBC GIS THE ENTIRE PARCEL IS LOCATED IN
 ONE AE FLOOD ZONE.
  
 7. LINE B9. PER PBC GIS THE BASE FLOOD ELEVATION (BFE)
 OF THE AE FLOOD ZONE IS 7'-0".
  
 8. LINE C2B). (SEE PLAN PAGES A-1.01 AND A03.02) IF TOP
 OF BOTTOM FLOOR (C2A) IS 9'-6" AND THE 2ND FLOOR IS
 +12'-6" THEN C2B) SHOULD BE 22'-0".
  
 9. LINE C2D). GARAGE TOS IS STATED AS 5'-3". PLAN PAGES
 A-1.01 AND A-3.02 STATES GARAGE TOS AS 8'-0". PLEASE
 CLARIFY.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  


Account Summary | Usage Policy | Privacy Policy