| 2022-10-04 18:16:47 | RESIDENTIAL (R3) ALTERATION SECOND BUILDING REVIEW |
| | COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #22071422 |
| | 236 EDGEWOOD DR (GARAGE/APARTMENT). |
| | |
| | |
| | NOTE: |
| | RESPONSE LETTER SUBMITTED IS FOR THE MAIN HOUSE |
| | COMMENTS NOT FOR THE GARAGE/APARTMENT. |
| | |
| | |
| | ORIGINAL COMMENT: |
| | 1- BEDROOM EGRESS WINDOWS DON'T COMPLY WITH THE MINIMUM |
| | CLEAR OPENING REQUIREMENTS OF SEC. R310.2.1 |
| | FBC-RESIDENTIAL. REVISE AS REQUIRED. |
| | |
| | RESPONSE: |
| | 1-SINGLE HUNG BEDROOM EGRESS WINDOWS SIZE (3'-0" X |
| | 5'-0")DOESN'T SEEM TO COMPLY WITH THE MINIMUM CLEAR |
| | HEIGHT OPENING REQUIREMENTS OF SEC. R310.2.1 |
| | FBC-RESIDENTIAL. REVISE AS REQUIRED OR PROVIDE |
| | MANUFACTURER'S SPECIFICATIONS SHOWING COMPLIANCE ALL |
| | THE EGRESS REQUIREMENTS. |
| | NOTE: TYPICALLY, 63" HIGH SINGLE HUNG WINDOWS ARE THE |
| | ONES THAT PROVIDE THE 24" CLEAR HEIGHT OPENING. |
| | |
| | 2- PRODUCT APPROVALS |
| | PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001 |
| | FOR: |
| | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED |
| | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW |
| | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL |
| | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL): |
| | |
| | A)INSWING ENTRY DOOR AS SHOWN ON PLANS. |
| | B)SINGLE HUNG WINDOWS. |
| | C)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE |
| | IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION |
| | SCHEDULE. SEE CITY SAMPLE. |
| | D)OVERHEAD GARAGE DOOR AS SHOWN ON PLANS. |
| | |
| | 3- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| | |
| | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND |
| | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE |
| | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |