| Plan Review Notes For Permit 22071340 |
| Permit Number |
22071340 |
|
| Review Stop |
R |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2023-07-17 07:57:59 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II/INSPECTOR | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | 3RD ROOFING REVIEW DENIED: | | | | | | FBC B 107.2.1, PROVIDE ENGINEER'S LETTER ADDRESSING NOA | | | # 20-0723.29 (LIMITATIONS #7) FOR ROOF ZONES 1, 2, & 3 | | | WINDLOAD PRESSURES, ANCHOR SPACING, AND ATTACHMENT OF | | | TAPERED INSULATION AS PER FBC R 906, BASE | | | SHEET/MODIFIED BITUMEN AS PER FBC R 905.11. | | | | | | NOTE: A ROOFING SUB-PERMIT IS REQUIRED PRIOR TO ROOF | | | WORK. |
|