 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) 2ND FLOOR CHANGE OF USE FROM STORAGE TO TRAINING
 AREA - PLEASE SHOW THE OCCUPANCY CLASSIFICATION FOR THE
 AREA FBC CHAPTER 3
  
 2) PLEASE SHOW THE OCCUPANT LOAD FOR THE TRAINING AREA
 - FBC 1004
  
 3) STAIR AND BALCONY GUARD RAIL OPENINGS FOR THE
 TRAINING AREA NEED TO COMPLY WITH FBC 1015.4 OPENING
 LIMITATIONS.
 REQUIRED GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW
 PASSAGE OF A SPHERE 4 INCHES (102 MM) IN DIAMETER FROM
 THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT.
  
 4) SHOW THE VERTICAL ACCESSIBILITY TO THE 2ND FLOOR PER
 FBC 201.1.1