| Plan Review Notes For Permit 22071166 |
| Permit Number |
22071166 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2022-09-13 16:54:27 | 1ST REVIEW FBC-2020 RES. PLUMBING | | | PERMIT- 22071166 | | | 9/13/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS 1 & 2: PLEASE SHOW THE LENGTH OF THE PIPING | | | RUNS AND TYPE AND NUMBER OF FITTINGS IN THE TDH | | | CALCULATIONS, AND PROVIDE THE PUMP CURVE ON THE PLAN | | | MARKED UP TO SHOW THE TDH AND FLOW RATE OF THE SYSTEM- | | | SECS. 4.4.9, 4.4.9.1 ANSI/APSP/ICC-7 & R4501.7.2 & | | | R4501.7.3 FBC RES. | | | | | | 2) SHEET 2: THE WATERWAY MAIN DRAIN AND COVER SPECIFIED | | | ON THE PLAN DOES NOT MATCH THE UPLOADED PENTAIR DRAIN | | | SUBMITTAL. PLEASE NOTE THE 160 GPM MAXIMUM FLOW RATE OF | | | THE SYSTEM EXCEEDS THE FLOW CAPACITIES OF THE TWO DRAIN | | | ASSEMBLIES- SEC. R4501.6.6 FBC RES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|