| Date |
Text |
| 2022-08-22 15:32:56 | 1ST REVIEW FBC-2020 PLUMBING |
| | PERMIT-22070805 |
| | 8/22/22 |
| | |
| | CODES IN EFFECT: |
| | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| | 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) SHEETS A.02 & P0.1: PROVIDE PLUMBING FIXTURE |
| | CALCULATIONS IN COMPLIANCE WITH TABLE 403.1 FBC P. IT |
| | APPEARS THE REQUIRED SERVICE SINK IS MISSING FROM THE |
| | PLANS. |
| | |
| | 2) P0.1 & P2.1: A MAXIMUM OF ONE FIXTURE DRAIN SHALL |
| | MAKE CONNECTION TO THE HORIZONTAL WET VENT UPSTREAM OF |
| | THE DRY VENTED FIXTURE DRAIN CONNECTION- SEC. 912.2.1 |
| | FBC P. PLEASE RELOCATE ONE OF THE TWO WATER CLOSET |
| | FIXTURE DRAINS SHOWN UPSTREAM OF THE LAVATORY DRAIN. |
| | |
| | 3) P0.1 & P2.1: THE KITCHEN SINK FIXTURE DRAIN SHALL |
| | NOT CONNECT TO THE HORIZONTAL WET VENT- SEC. 912.1 FBC |
| | P. |
| | |
| | 4) A4.21: PROVIDE THE FOLLOWING DETAILS PER THE FBC |
| | ACC. |
| | A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE |
| | WATER CLOSETS- SEC. 604.3. |
| | B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE |
| | LAVATORIES- SEC. 606.2. |
| | C) TURNING SPACE DIAMETERS- SEC. 304.3. |
| | D) HEIGHTS OF THE MIRRORS FROM THE FINISHED FLOORS TO |
| | THE REFLECTIVE SURFACES- SEC. 603.3. |
| | |
| | 5) A0.02 & 4.21: THE DRINKING FOUNTAINS ARE PROTRUDING |
| | INTO THE CIRCULATION PATH. THE MAXIMUM ALLOWABLE |
| | PROTRUSION IS 4-INCHES- SEC. 307.2 FBC ACC. |
| | |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |