| 2022-12-07 16:10:41 | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD |
| | INSPECTOR'S APPROVAL |
| | |
| | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE |
| | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN |
| | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM |
| | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND |
| | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF |
| | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY |
| | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM |
| | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES |
| | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO |
| | AVOID VOIDING OF THE PERMIT. |
| | |
| | PROVISO: PROVIDE CANE APRON FOR DRINKING FOUNTAIN. SEE |
| | A-601, DRINKING FOUNTAIN DETAIL, NOTE 6 AND FBC ACC |
| | 307.2 |
| | |
| | PROVISO: EEMAX EMT1.0 AND EEMAX EMT2.5 NOT SERVICING |
| | PUBLIC LAVATORIES SHALL BE PROVIDED WITH A TEMPERATURE |
| | ACTUATED MIXING VALVE CONFORMING TO ASSE 1017 PER FBC |
| | PL 607.1.1, 613.1 |
| | THOSE SERVICING PUBLIC LAVATORIES SHALL BE PROVIDED |
| | WITH A WATER TEMPERATURE LIMITING DEVICE CONFORMING TO |
| | ASSE 1070 PER FBC PL FPC 419.5, 607.1.2 |
| | |
| | PROVISO: THE REVERSE OSMOSIS SYSTEM IN THE KITCHEN |
| | SHALL BE PROVIDED WITH AN INDIRECT WASTE TO THE FLOOR |
| | SINK WITH AN AIR GAP. FPC 802.1.1 |
| | THE WATER SUPPLY TO THE REVERSE OSMOSIS SYSTEM SHALL BE |
| | PROVIDED WITH A BACKFLOW PREVENTER. FPC 608.1 |
| | |