| 2022-08-02 16:01:56 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE |
| | MARSHAL, WITH THE FOLLOWING COMMENTS: |
| | |
| | |
| | 1) THERE IS NO INDICATION OF A SITE PLAN SHOWING THE |
| | LOCATION OF THE PROPOSED STAIR. |
| | |
| | PER NFPA 1 |
| | |
| | 1.7.12 PLANS AND SPECIFICATIONS. |
| | |
| | 1.7.12.1 THE AHJ SHALL HAVE THE AUTHORITY TO REQUIRE |
| | PLANS AND SPECIFICATIONS TO ENSURE COMPLIANCE WITH |
| | APPLICABLE CODES AND STANDARDS. |
| | |
| | 1.7.12.6 PLANS SHALL BE SUBMITTED TO THE AHJ PRIOR TO |
| | THE ALTERATION OF THE MEANS OF EGRESS OR FIRE |
| | PROTECTION SYSTEMS OF ANY EXISTING BUILDING. |
| | |
| | PLEASE PROVIDE A DETAILED SITE PLAN. |
| | |
| | |
| | 2) THERE IS NO INDICATION OF THE EXIT DOOR NOR LANDING |
| | FROM THE EXIT DOOR. |
| | |
| | 1.7.12.6 PLANS SHALL BE SUBMITTED TO THE AHJ PRIOR TO |
| | THE ALTERATION OF THE MEANS OF EGRESS OR FIRE |
| | PROTECTION SYSTEMS OF ANY EXISTING BUILDING. |
| | |
| | PLEASE PROVIDE DETAILS OF THE EXIT DOOR AND EXIT DOOR |
| | LANDING. |
| | |
| | |
| | |
| | 3) THERE IS NO INDICATION OF THE BOTTOM LANDING AREA |
| | FROM THE STAIRS THAT IS FREE AND CLEAR TO A PUBLIC WAY. |
| | |
| | 1.7.12.6 PLANS SHALL BE SUBMITTED TO THE AHJ PRIOR TO |
| | THE ALTERATION OF THE MEANS OF EGRESS OR FIRE |
| | PROTECTION SYSTEMS OF ANY EXISTING BUILDING. |
| | |
| | PLEASE PROVIDE DETAILS OF THE BOTTOM LANDING AREA. |
| | |
| | |
| | |
| | 4) THERE IS NO INDICATION OF ANY WALL NOR |
| | OPENINGS/WINDOWS ALONG THE EXIT STAIR THAT MAY REQUIRE |
| | PROTECTION FOR THOSE USING THE EXIT STAIR. |
| | |
| | PER NFPA 101 CH 7, MEANS OF EGRESS |
| | |
| | 7.2.2.5.2.1 WHERE NONRATED WALLS OR UNPROTECTED |
| | OPENINGS ENCLOSE THE |
| | EXTERIOR OF A STAIRWAY, OTHER THAN AN EXISTING |
| | STAIRWAY, AND THE WALLS OR |
| | OPENINGS ARE EXPOSED BY OTHER PARTS OF THE BUILDING AT |
| | AN ANGLE OF LESS |
| | THAN 180 DEGREES, THE BUILDING ENCLOSURE WALLS WITHIN |
| | 10 FT (3050 MM) |
| | HORIZONTALLY OF THE NONRATED WALL OR UNPROTECTED |
| | OPENING SHALL BE CON STRUCTED AS REQUIRED FOR STAIRWAY |
| | ENCLOSURES, INCLUDING OPENING |
| | PROTECTIVES. |
| | 7.2.2.5.2.2 CONSTRUCTION SHALL EXTEND VERTICALLY FROM |
| | THE FINISHED GROUND |
| | LEVEL TO A POINT 10 FT (3050 MM) ABOVE THE TOPMOST |
| | LANDING OF THE STAIRS |
| | OR TO THE ROOFLINE, WHICHEVER IS LOWER. |
| | 7.2.2.5.2.3 THE FIRE RESISTANCE RATING OF THE |
| | SEPARATION EXTENDING 10 FT |
| | (3050 MM) FROM THE STAIRS SHALL NOT BE REQUIRED TO |
| | EXCEED 1 HOUR WHERE |
| | OPENINGS HAVE A MINIMUM 3 |
| | ?4-HOUR FIRE PROTECTION RATING. |
| | |
| | PLEASE PROVIDE DETAILS OF ALL OPENINGS ALONG THE WALL. |
| | IF NOT APPLICABLE, PROVIDE JUSTIFICATION. |
| | |
| | |
| | |
| | 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET |
| | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE |
| | ABOVE. |
| | |
| | |