| Date |
Text |
| 2023-01-10 09:06:47 | STORAGE ROOM ADDITION |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| | AMENDMENT |
| | |
| | CORRECTIONS NEEDED - |
| | |
| | 1) THE SITE PLAN NEEDS TO SHOW THE LOT DRAINAGE AWAY |
| | FROM THE BUILDING AND AWAY FROM THE ADJACENT PROPERTY |
| | OR PROVIDE A STORM WATER DRAINAGE PLAN. - PLEASE |
| | PROVIDE A SURVEY/SITE PLAN SHOWING THE FOLLOWING |
| | INFORMATION - FBC WPB 107.2.5 SITE PLAN. THE |
| | CONSTRUCTION DOCUMENTS SUBMITTED WITH THE APPLICATION |
| | FOR PERMIT SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING |
| | TO SCALE THE SIZE AND LOCATION OF NEW CONSTRUCTION AND |
| | EXISTING STRUCTURES ON THE SITE, DISTANCES FROM LOT |
| | LINES, THE ESTABLISHED STREET GRADES AND THE PROPOSED |
| | FINISHED GRADES, DEPICTING THE PROPOSED LOT DRAINAGE |
| | AND, AS APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND |
| | DESIGN FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN |
| | ACCORDANCE WITH AN ACCURATE AND INCLUDED ON A BOUNDARY |
| | LINE SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY |
| | PROPOSED WATER RETAINING SWALES) |
| | |
| | 2) PLEASE SHOW THE EMERGENCY ROOF DRAIN SCUPPER |
| | DISTANCE FROM THE ROOF SURFACE - FBC 1503.4.2.1 |
| | OVERFLOW SCUPPERS. WHEN OTHER MEANS OF DRAINAGE OF |
| | OVERFLOW WATER IS NOT PROVIDED, OVERFLOW SCUPPERS SHALL |
| | BE PLACED IN WALLS OR PARAPETS NOT LESS THAN 2 INCHES |
| | (51 MM) NOR MORE THAN 4 INCHES (102 MM) ABOVE THE |
| | FINISHED ROOF COVERING |
| | |
| | 3) PLEASE SHOW THE ROOF DRAIN SCUPPER LEVEL WITH THE |
| | ROOF SURFACE - FBC 1503.4.2 SCUPPERS. WHERE REQUIRED |
| | FOR ROOF DRAINAGE, A SCUPPER SHALL BE PLACED LEVEL WITH |
| | THE ROOF SURFACE IN A WALL OR PARAPET. (DRAWING A-301 |
| | DETAIL 2 - SHOWS THE ROOF SCUPPER TOO HIGH ABOVE THE |
| | ROOF) |
| | |
| | 4) DRAWING G-000 - UNDER "PROJECT DESCRIPTION" |
| | RESIDENTIAL CODE SHOULD NOT BE MENTIONED. |
| | |
| | 5) PLEASE PROVIDE THE FRONT PAGE OF THE ROOFING SYSTEM |
| | FLORIDA STATE PRODUCT APPROVAL (FL31780) |
| | |
| | 6) SOME DRAWINGS STILL SHOW A NEW EXTERIOR DOOR - |
| | A-301, E-101 - ALL DRAWINGS SHOULD MATCH. |
| | |
| | |