Plan Review Notes
Plan Review Notes For Permit 22070389
Permit Number 22070389
Review Stop P
Sequence Number 3
Notes
Date Text
2022-10-21 16:51:17 
 3RD REVIEW FBC-2020 PLUMBING
 PERMIT-22070389
 10/21/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE
 1ST REVIEW AND 2ND REVIEW ARE LISTED BELOW WITH
 ADDITIONAL NOTES.
  
 1) P2.1 THE SANITARY DRAWING SHOWS DRAINAGE FROM THE
 ICE CHESTS (B.5 & B.8) AND ICE MAKERS (B.11 & B.12)
 DISCHARGING INTO THE GREASE WASTE LINE INSTEAD OF THE
 SANTARY AS REQUIRED - SEC. 1003.3.1 FBC P.
  
 2) P5.1: THE REVISED SANITARY ISOMETRIC THE RISER SHOWS
 DRAINAGE FROM THE ICE CHESTS (B.5 & B.8) AND ICE MAKERS
 (B.12) DISCHARGING INTO THE GREASE WASTE LINE INSTEAD
 OF THE SANTARY AS REQUIRED- SEC. 1003.3.1 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  