| Plan Review Notes For Permit 22070117 |
| Permit Number |
22070117 |
|
| Review Stop |
G |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2022-08-17 08:58:19 | | | | 2ND REVIEW FBC-2020 RES. GAS | | | PERMIT- 22070117 | | | 8/17/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. COMMENTS PRINTED BELOW | | | FROM THE 1ST REVIEW WERE NOT ADDRESSED- PLEASE COMPLY. | | | | | | 1) GAS RISER: REVISE THE RISER DRAWING TO SHOW THE | | | EXISTING GAS PIPING TO THE POOL HEATER APPROVED UNDER | | | PERMIT- 22061538. IT IS ACKNOWLEDGED THAT INSTALLATION | | | OF THE POOL HEATER IS NOT IN THE SCOPE OF THIS PERMIT | | | HOWEVER A COMPLETE GAS RISER IS REQUIRED UNDER THIS | | | PERMIT BASED ON SECS. G2412.3 & G2412.4 FBC RES. | | | | | | 2) GAS RISER: SHOW THE SIZE OF THE MAIN SUPPLY PIPE | | | FROM THE METER TO THE 1ST TEE- TABLE 402.4(5) FBC FG. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|