Plan Review Notes
Plan Review Notes For Permit 22070105
Permit Number 22070105
Review Stop B
Sequence Number 3
Notes
Date Text
2022-12-28 13:42:04RESIDENTIAL (R3) REVISION, ADDITION/ALTERATION THIRD
 BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PRMIT #22070105
 213 MARLBOROUGH RD
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES APPLY (NOTE: FEES DON'T
 APPLY TO PRODUCT APPROVAL SUBMITTAL, EXCEPT FOR PRODUCT
 APPROVALS ALREADY REVIEWED/APPROVED).
  
 ***IMPORTANT****CONTRACTOR TO ADVICE IF PROVISO OPTION
 IS PREFERRED AT THIS TIME OR IF RE-SUBMITTING REQUIRED
 INFORMATION BEFORE PERMIT ISSUANCE.
  
  
 1-6 OK.
  
 ORIGINAL COMMENT:
 7- PROVIDE COMPLETE FRAMING PLANS, SECTIONS AND
 SPECIFICATIONS FOR RE-CONSTRUCTION OF WOOD CORNICE &
 BARREL TILE ROOF SHOWN ON PLANS FOR FIRST FLOOR.
 SPECIFY ALL FRAMING MEMBERS AND CONNECTORS, ETC. SEC.
 R301.2.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 PARAPET DETAIL ON SHEET A-01 IS INCOMPLETE. IT DOESN'T
 SPECIFY ALL FRAMING MEMBERS AND ALL CONNECTORS FOR
 PARAPET WALL. NEED TO PROVIDE THIS INFORMATION.
  
 ORIGINAL COMMENT:
 8- CLARIFY/REVISE SIZE OF EMERGENCY OVERFLOW SCUPPERS
 SPECIFIED ON PLANS. SEC. R903.4.1 FBC-RESIDENTIAL.
 NOTE: 2" EMERGENCY OVERFLOW SCUPPER DOESN'T COMPLY.
  
 RESPONSE:
 EMERGENCY OVERFLOW SCUPPER SIZE (4"H X 2"W) DOESN'T
 COMPLY. SEE SEC. 1108.3 FBC-PLUMBING AS REQUIRED BY
 SEC. R903.4.1 FBC-RESIDENTIAL AND REVISE SIZE.
  
 9- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 ORIGINAL COMMENT:
 A)FLAT ROOF AND CLEARLY MARK/IDENTIFY WHICH ASSEMBLY IS
 GOING TO BE INSTALLED. IF SELECTED ASSEMBLY DOESN'T
 MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN
 SIGNED AND SEALED RAS 117 CALCULATIONS ARE REQUIRED.
  
 RESPONSE:
 THERE ARE TWO DIFFERENT PRODUCT APPROVALS UPLOADED IN
 THE SAME PDF FILE. ONE IS CERTAINTEED FLORIDA PRODUCT
 APPROVAL FL2533-R28 AND THE OTHER ONE IS CERTAINTEED
 NOA 17-1003.15. IMPORTANT NEED TO SUBMIT ONLY ONE
 PRODUCT APPROVAL TO AVOID CONFLICTS.
  
 NOTE:
 EITHER PRODUCT APPROVAL REQUIRES SIGNED AND SEALED RAS
 117 CALCULATIONS BECAUSE THE SELECTED ASSEMBLIES DON'T
 MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES. THE
 MAXIMUM DESIGN PRESSURES (MDP) ON SELECTED ASSEMBLY
 W-77 CERTAINTEED FLORIDA PRODUCT APPROVAL FL2533-R28 IS
 -60PSF. AND THE DESIGN PRESSURES ON CERTAINTEED NOA
 17-1003.15 WERE NO IDENTIFIED BECAUSE NO ASSEMBLY WAS
 SELECTED. NEVERTHELESS NONE OF THE ASSEMBLIES ON NOA
 SUBMITTED MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES.
 NOTE: WHEN SELECTING AN ASSEMBLY MAKE SURE SELECTED
 ASSEMBLY IS NOT LIMITED BY GENERAL LIMITATION #9
 BECAUSE THIS LIMITATION DOESN'T ALLOW NAIL ENHANCEMENT.
 SEE GENERAL LIMITATION #9 ON LAST PAGE OF NOA.
 SEC.107.2.1 CITY AMENDMENTS.
  
 PREVIOUS COMMENT:
 B) ARCHITECT'S RESPONSE LETTER STATES "GC REVISED
 OUTSWING FRENCH DOOR SUBMITTAL. NEW SUBMITTAL
 ATTACHED.".
 NOTHING WAS UPLOADED TO PROJECTDOX FOR REVIEW.
 NOTE: NEED PRODUCT APPROVAL FOR INSWING FRENCH DOORS AS
 SHOWN ON THE SECOND FLOOR. CHECK DESIGN PRESSURES
 SPECIFIED ON PLANS.
  
 RESPONSE:
 PRODUCT APPROVAL FOR SINGLE "OUTSWING" DOOR WAS
 SUBMITTED BUT PRODUCT APPROVAL FOR DOUBLE INSWING DOORS
 WAS NOT SUBMITTED.
  
 ORIGINAL COMMENT:
 C)ROOF TILE AND CLEARLY MARK ADHESIVE PADDY SIZE TO BE
 USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS
 TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC
 R301.2.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 THERE ARE TWO DIFFERENT PRODUCT APPROVALS UPLOADED IN
 THE SAME PDF FILE. ONE IS CERAMICA VEREA FLORIDA
 PRODUCT APPROVAL FL17152-R4 AND THE OTHER ONE IS TEJAS
 VEREA NOA 20-0902.03. IMPORTANT NEED TO SUBMIT ONLY ONE
 PRODUCT APPROVAL AND CLEARLY MARK FASTENING METHOD TO
 AVOID CONFLICTS
 NOTE: FLORIDA PRODUCT APPROVAL FL17152-R4 IS NOT MARKED
 SHOWING THE FASTENING METHOD. NOA 20-0902.03 IS MARKED
 WITH AH-160 ADHESIVE ON PAGE 5 OF 9. THIS FASTENING
 METHOD IS OK FOR ALL ROOF ZONES BUT ADHESIVE PRODUCT
 APPROVAL SUBMITTED DOESN'T MATCH AH-160 ADHESIVE LISTED
 IN THE NOA. COORDINATE AS REQUIRED TO AVOID MORE
 CONFLICTS/DELAYS. SEC.107.2.1 CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 D)PROVIDE A ROOF TILE ADHESIVE PRODUCT APPROVAL THAT IS
 LISTED ON THE ROOF TILE PRODUCT APPROVAL SUBMITTED.
  
 RESPONSE:
 COORDINATE WITH ITEM #9(C) ABOVE TO AVOID MORE
 CONFLICTS/DELAYS. SEC.107.2.1 CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 E) HIP AND RIDGE INSTALLATION TO BE USED. AND, CLEARLY
 MARK ON PRODUCT APPROVAL ATTACHMENT METHOD. SEC.
 R905.3.7.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 FLORIDA PRODUCT APPROVAL FL5374-R6 SUBMITTED IS OK.
 NOTE: COORDINATE ROOF TILE ADHESIVE WITH ITEM #9(C)
 ABOVE TO AVOID MORE CONFLICTS/DELAYS. SEC.107.2.1 CITY
 AMENDMENTS.
  
 ORIGINAL COMMENT:
 10- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 RESPONSE:
 NOT ADDRESSED.
 NOTE: THIS COMMENT APPLIES TO ALL PRODUCT APPROVALS
 SUBMITTED, INCLUDING ONES SUBMITTED EARLIER.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
  