| Plan Review Notes For Permit 22070066 |
| Permit Number |
22070066 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2022-08-23 11:54:25 | 1ST REVIEW FBC-2020 RES. PLUMBING | | | PERMIT- 22070066 | | | 8/23/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. THE REVIEW IS BASED ON | | | UPDATED PLUMBING PLANS. | | | | | | 1) SHEET P-1: THE REVISED PLAN SHOWS EXISTING 1/2-INCH | | | WATER LINES WHICH WILL HAVE TO BE INCREASED IN SIZE IN | | | SPECIFIC AREAS IN ORDER TO ACCOMMODATE THE ADDITIONAL | | | NEW PLUMBING FIXTURES AND INCREASE IN WSFU DEMAND- SEE | | | TABLES P2903.1 & P2903.6 FBC RES. PLEASE PROVIDE A | | | WATER RISER DRAWING- SEC. 107.3.5.3 WPB. | | | | | | 2) SHEET P-1: A NEW GAS-FIRED TANKLESS WATER HEATER HAS | | | BEEN ADDED ON THE EXTERIOR OF THE HOUSE. A SEPARATE GAS | | | REVIEW HAS BEEN SET UP- PLEASE REFER TO THOSE COMMENTS. | | | CONCERNING THE PLUMBING, THE WATER HEATER SHALL BE | | | SIZED LARGE ENOUGH TO SUPPLY HOT WATER TO THE INCREASED | | | NUMBER OF PLUMBING FIXTURES. PLEASE REVIEW THE | | | MANUFACTURER?S GUIDELINES FOR HOT WATER PIPE SIZING | | | RECOMMENDATIONS AND SHOW THE PIPE SIZES IN THE RISER | | | DRAWING- SEC. 107.3.5.3 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|