2022-09-21 16:33:44RESIDENTIAL (R3)ADDITION/ALTERATION SECOND BUILDING
 REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22061666
 6205 WASHINGTON RD
  
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES MAY APPLY.
 ***IMPORTANT****CONTRACTOR TO ADVICE IF PROVISO OPTION
 IS PREFERRED AT THIS TIME OR IF RE-SUBMITTING REQUIRED
 INFORMATION BEFORE PERMIT ISSUANCE.
  
  
  
 ORIGINAL COMMENT:
 1- UNABLE TO PERFORM REVIEW. MISSING
 STRUCTURAL/ARCHITECTURAL DRAWINGS FOR CONSTRUCTION OF
 PROPOSED ADDITION/ALTERATION. SEC. 107.5.5.2 CITY
 AMENDMENTS. SEC. R301.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 A)ROOF FRAMING PLAN ON SHEET 8.0: PROVIDE SECTION
 DETAIL FOR NEW (2)1-3/4"X16" LVL BEAM SHOWING HOW THE
 SIMPSON HANGER HU314-2 IS INSTALLED AT EACH END OF
 BEAM. NOTE: ACCORDING TO WALL SECTION S1/5.0 THIS BEAM
 IS SITTING ON TOP OF THE MASONRY WALL.
 SEC. 107.2.1 CITY AMENDMENTS. SEC. R301.1
 FBC-RESIDENTIAL.
  
 B)ROOF FRAMING PLAN ON SHEET 8.0: THERE IS NOT BEAM
 SCHEDULE PROVIDING SPECIFICATIONS FOR BEAM ML2 SHOWN ON
 THE FRONT AND REAR ADDITIONS. PROVIDE BEAM SCHEDULE.
 SEC. 107.2.1 CITY AMENDMENTS. SEC. R301.1
 FBC-RESIDENTIAL.
  
 C)ENGINEER OF RECORD TO REVISE ROOF SHEATHING NAILING
 SPECIFICATIONS TO COMPLY WITH NEW 2020 FBC-RESIDENTIAL
 SPECIFICATIONS. NAIL SPACING TO COMPLY TABLE R803.2.3.1
 FBC-RESIDENTIAL. NAIL SPACING TO BE 4" 0.C.
 NOTE: REVISE SPECIFICATIONS OR PROVIDE CALCULATIONS
 SHOWING THAT SPECIFIED NAIL TYPE AND SPACING MATCHES OR
 EXCEEDS TABLE R803.2.3.1 FBC-RESIDENTIAL MINIMUM
 REQUIREMENTS
  
 D)ENGINEER TO PROVIDE DETAIL OF NEW BEARING KNEE WALL
 OVER EXISTING ROOF STRUCTURE AS SPECIFIED ON WALL
 SECTION S3/5.1. SPECIFY ALL FRAMING MEMBERS AND
 CONNECTORS. SEC. 107.2.1 CITY AMENDMENTS. SEC. R301.1
 FBC-RESIDENTIAL.
  
 E) ENGINEER TO SPECIFY ROOF CROSS VENTILATION AS
 REQUIRED BY SEC. R806 FBC-RESIDENTIAL. SPECIFY VENT
 SIZE AND LOCATION.
  
 F)PROVIDE DOOR AND WINDOW STRUCTURAL BUCK DETAIL
 SHOWING COMPLIANCE WITH SEC. R609.7.2.1
 FBC-RESIDENTIAL. SPECIFY STRUCTURAL BUCK SIZE AND
 FASTENING.
 NOTE: STRUCTURAL BUCK NEEDS TO PROVIDE FULL SUPPORT TO
 THE DOOR/WINDOW FRAME AS REQUIRED BY SEC. R609.7.2.1
 FBC-RESIDENTIAL.
  
 G)SOFFIT CONSTRUCTION DETAIL ON WALL SECTIONS: ENGINEER
 TO PROVIDE SPECIFICATIONS FOR TYPE OF METAL PLASTER
 BASE FOR CEILINGS SHOWING COMPLIANCE WITH TABLE 3 OF
 ASTM C1063.
 NOTE: ALSO, PROVIDE DETAIL/SPECIFICATIONS FOR CEILING
 CONSTRUCTION AT NEW MASTER LANAI.
  
 H)SHEET 6.1: ENGINEER TO REVISE END ZONE DISTANCE. THE
 MINIMUM DIMENSION IS 4'-0" NOT 3'-0" AS REQUIRED BY
 NOTE "A" ON FIGURE R301.2(7) FBC-RESIDENTIAL. REVISE AS
 REQUIRED.
  
 I)TRUSS PACKAGE NEEDS TO BE REVIEWED AND APPROVED BY
 THE ENGINEER OF RECORD.
 NOTE: PLEASE DON'T RESUBMIT THE TRUSS PACKAGE AFTER IT
 IS APPROVED BY THE ENGINEER OF RECORD. THE APPROVED
 TRUSS PACKAGE NEEDS TO BE HANDLED TO THE BUILDING
 INSPECTOR DURING THE FRAMING INSPECTION.
  
 J) INTERIOR DESIGN DRAWINGS ARE NOT REQUIRED TO BE
 SUBMITTED. IF CONTRACTOR WANT TO SUBMIT THEM, THEN THEY
 NEED TO BE PROPERLY SIGNED AND SEALED BY THE INTERIOR
 DESIGNER OF RECORD AS REQUIRED BY CHAPER 481 F.S. WHEN
 SUBMITTING THEM FOR PUBLIC RECORDS.
  
  
 2- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 ORIGINAL COMMENT:
 A)EXTERIOR DOORS AS SHOWN ON PLANS.
  
 RESPONSE:
 JELD-WEN FLORIDA PRODUCT APPROVAL FL16708-R13 IS
 INCOMPLETE. NEED INSTALLATION INSTRUCTIONS DRAWINGS.
  
 B)OK.
  
 ORIGINAL COMMENT:
 C)WINDOW MULLIONS (NOTE: NEED TO SPECIFY MULLION SIZE
 TO VERIFY PRESSURES. SEC. R301.2.1 FBC-RESIDENTIAL).
  
 RESPONSE:
 NOT ADDRESSED.
  
 D)OK.
  
 ORIGINAL COMMENT:
 E)ROOF TILE AND CLEARLY MARK ADHESIVE PADDY SIZE TO BE
 USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS
 TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC
 R301.2.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 FLORIDA PRODUCT APPROVAL FL17330-R4 IS INCOMPLETE.
 MISSING INSTALLATION INSTRUCTIONS. ALSO, NEED TO
 SPECIFY PADDY SIZE.
  
 ORIGINAL COMMENT:
 F)ROOF TILE ADHESIVE LISTED IN ROOF TILE PRODUCT
 APPROVAL.
  
 RESPONSE:
 NOT ADDRESSED.
  
 ORIGINAL COMMENT:
 G)ROOFING UNDERLAYMENT SPECIFIED ON PLANS.
  
 RESPONSE:
 SINGLE PLY ROOF SYSTEMS FL14318-R18 SUBMITTED IS NOT A
 ROOF TILE UNDERLAYMENT. THIS IS ROOFING ASSEMBLY FOR
 FLAT ROOFS.
  
 ORIGINAL COMMENT:
 H)HIP & RIDGE METAL SUPPORT TO BE USED.
  
 RESPONSE:
 NOT ADDRESSED.
  
 ORIGINAL COMMENT:
 3- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 RESPONSE:
 NOTE: ROOFING UNDERLAYMENT INFO ON PRODUCT APPROVAL
 SCHEDULE ON SHEET 3.1 IS INCORRECT. SINGLE PLY ROOF
 SYSTEMS FL14318-R18 SUBMITTED IS NOT A ROOF TILE
 UNDERLAYMENT. THIS IS ROOFING ASSEMBLY FOR FLAT ROOFS.
 REVISE AS REQUIRED AND INCLUDE MISSING PRODUCT
 APPROVALS.
  
  
 4- ENERGY CALCULATIONS SUBMITTED:
 A)OK.
 B)OK.
  
 ORIGINAL COMMENT:
 C)NUMBER OF BEDROOMS ON PAGE 1 IS INCORRECT. SEE PLANS
 AND REVISE AS REQUIRED. SECTION R101.5.1.1.2
 FBC-RESIDENTIAL.
  
 RESPONSE:
 NUMBER OF BEDROOMS IS INCORRECT AGAIN. SEE PLANS AND
 REVISE.
  
 D)OK.
 E)OK.
  
 ORIGINAL COMMENT:
 F)CEILING TYPE INFORMATION ON PAGE 1 IS NOT CLEAR.
 CLARIFY WHY ENTERING TILE, SLATE, CONC.?. THIS IS NOT A
 CEILING TYPE. ALSO, NEED TO SPECIFY IF THE CEILING IS
 VENTED OR NOT. THIS NEEDS TO BE COORDINATED WITH THE
 INFORMATION SHOWN ON PLANS. REVISE AS REQUIRED. SECTION
 R101.5.1.1.2 FBC-RESIDENTIAL.
 NOTE: ARCHITECTURAL PLANS WERE NOT SUBMITTED FOR
 REVIEW. THIS INFORMATION WILL BE REVIEWED WHEN PLANS
 ARE SUBMITTED.
  
 RESPONSE:
 CEILING R-VALUE DOESN'T MATCH PLANS. ENGINEER OF RECORD
 SPECIFIES R20 NOT R25.
  
 G)OK.
 H)OK.
 I)OK.
  
 ORIGINAL COMMENT:
 J)DOORS INFORMATION ON PAGE 4 CAN NOT BE REVIEWED AT
 THIS TIME. ARCHITECTURAL PLANS AND PRODUCT APPROVALS
 WERE NOT SUBMITTED FOR REVIEW. THIS INFORMATION WILL BE
 REVIEWED WHEN PLANS ARE SUBMITTED.
 NOTE: KEEP IN MIND THAT DOORS WITH GLAZING NEED TO BE
 ENTERED IN THE GLAZING SECTION NOT IN DOORS.
  
 RESPONSE:
 DOORS ORIENTATION DOESN'T MATCH PLANS.
  
 ORIGINAL COMMENT:
 K)WINDOWS INFORMATION ON PAGE 4 CAN NOT BE REVIEWED AT
 THIS TIME. ARCHITECTURAL PLANS AND PRODUCT APPROVALS
 WERE NOT SUBMITTED FOR REVIEW. THIS INFORMATION WILL BE
 REVIEWED WHEN PLANS ARE SUBMITTED: WINDOWS AREA, AND
 OVERHANG DEPTH AND SEPARATION.
  
 RESPONSE:
 WINDOWS ORIENTATION, MATERIAL, AND OVERHANG SEPARATIOON
 DON'T MATCH PLANS. REVISE AS REQUIRED.
  
 ORIGINAL COMMENT:
 L)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL
 (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY
 CONSERVATION.
  
 RESPONSE:
 NOT ADDRESSED.
  
 NEW COMMENT:
 M)TYPICALLY THE ATTIC VENT RATIO IS 1/150. ENGINEER
 CERTIFYING THE ENERGY CALCULATIONS SPECIFIES 1/300
 ATTIC VENT RATIO ON PAGE 4. PLANS DON'T SHOW THIS
 VENTILATION RATIO.
 ENGINEER CERTIFYING THE ENERGY CALCULATIONS TO PROVIDE
 COMPLETE DETAILS AND SPECIFICATIONS SHOWING COMPLIANCE
 WITH THE EXCEPTION OF SEC. R806.2 FBC-RESIDENTIAL WHEN
 SPECIFYING A VENT RATIO OF 1/300.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]