| Date |
Text |
| 2022-08-15 15:27:59 | 1ST REVIEW FBC-2020 RES. GAS |
| | PERMIT- 22061647 |
| | 8/15/2022 |
| | |
| | CODES IN EFFECT: |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION |
| | 2020 |
| | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| | 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) GAS RISER: THE RISER DRAWING IS INCOMPLETE BECAUSE |
| | IT DOES NOT SHOW THE PREVIOUS LOW PRESSURE PIPING AND |
| | APPLIANCES APPROVED UNDER PERMIT 19051480. WHEN NEW GAS |
| | PIPING AND APPLIANCES ARE ADDED TO AN EXISTING SYSTEM A |
| | COMPLETE RISER IS REQUIRED IN ACCORDANCE WITH SECS. |
| | G2412.3 & G2412.4 FBC RES. PLEASE REVISE THE RISER TO |
| | SHOW: |
| | A) TOTAL BTU LOAD OF THE SYSTEM AND INDIVIDUAL |
| | APPLIANCE BTU LOADS. |
| | B) TYPES AND SIZES OF PIPING. |
| | C) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER |
| | TO THE MOST REMOTE APPLIANCE OUTLET. |
| | D) BRANCH AND CUT PIPE LENGTH MEASUREMENTS. |
| | E) LOCATIONS OF REGULATORS AND INLET AND OUTLET |
| | PRESSURES AT REGULATORS. |
| | F) LOCATIONS AND TYPES OF PIPE SLEEVES. |
| | G) PIPE SIZING TABLES. |
| | |
| | 2) SURVEY: THE SURVEY INDICATES CONNECT GENERATOR TO |
| | EXISTING NG, THE RISER SHOWS NEW PIPING FROM THE METER- |
| | PLEASE CORRECT PER SEC. 107.2.1 WPB. |
| | |
| | 3) SURVEY: THE GENERATOR SHALL BE LOCATED A MINIMUM OF |
| | 10 FT. FROM AIR INTAKES INTO THE BUILDING- SEC. |
| | R303.5.1 FBC RES. PLEASE CORRECT THE NOTE INDICATING 5 |
| | FT. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |