| Plan Review Notes For Permit 22061479 |
| Permit Number |
22061479 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2022-07-25 17:45:15 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC R 301, REVISE PLAN TO INCLUDE WIND DESIGN | | | CRITERIA AND DESIGN PRESSURES FOR THE WINDOW. | | | | | | 2. FBC 107, EITHER SUBMIT A WINDOW PRODUCT APPROVAL, | | | REVIEWED BY ARCHITECT, OR REVISE PLAN TO INDICATE THAT | | | THIS WILL BE DEFERRED. | | | | | | 3. FS481, THE DIGITAL SIGNATURE IS INVALID IN ADOBE AND | | | SHOWS THAT CHANGES WERE MADE TO THE PLAN AFTER SIGNING | | | IN BLUEBEAM. PLEASE UPLOAD DIGITALLY SIGNED DOCUMENTS | | | WITH A VALID DIGITAL SIGNATURE. IF YOU WOULD LIKE TO | | | EMAIL A PAGE TO ME TO VERIFY PLEASE SEND TO | | | [email protected]. | | | | | | | | | |
|