| Plan Review Notes For Permit 22061263 |
| Permit Number |
22061263 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2022-09-24 13:01:46 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | WHISPERMAT CS WITH VINYL FLOORING IS PROPOSED. | | | WE HAVE TEST REPORTS FOR STC/IIC ON FILE. | | | THE FLAME SPREAD TEST WE HAVE ON FILE FOR WHISPERMAT CS | | | IS FOR USE WITH TILE. WE DO HAVE FLAME SPREAD TEST FOR | | | WHISPERMAT LVT. | | | | | | PROVIDE THE FLAME SPREAD TEST FOR WHISPERMAT CS | | | (WITHOUT TILE), OR PROPOSE A DIFFERENT PRODUCT WHICH | | | HAS THE TEST. IF YOU WISH TO USE WHISPERMAT LVT OR | | | ANOTHER PRODUCT WE HAVE ON FILE, WE WILL PROVIDE THE | | | TEST REPORTS FOR YOU. | | | | | | C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. | | | | | | | | | | | | |
|