Plan Review Notes
Plan Review Notes For Permit 22061263
Permit Number 22061263
Review Stop FIRE
Sequence Number 1
Notes
Date Text
2022-06-28 10:42:20THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE IS NO FLOOR PLAN SUBMITTED THAT INDICATES THE
 LOCATION OF THE BATHROOM NOR IF THEY ARE LOCATED ALONG
 A TENANT SEPARATION WALL REQUIRING MAINTENANCE/REPAIR
 OF THE FIRE RATED WALL SHOULD THE DEMO DAMAGE THAT
 WALL.
  
 PER NFPA 1
  
 1.7.12 PLANS AND SPECIFICATIONS.
  
 1.7.12.1 THE AHJ SHALL HAVE THE AUTHORITY TO REQUIRE
 PLANS AND SPECIFICATIONS TO ENSURE COMPLIANCE WITH
 APPLICABLE CODES AND STANDARDS.
  
 FOR THE OFFICIAL RECORD, PLEASE PROVIDE A FLOOR PLAN
 INDICATING THE LOCATION OF THE BATHROOM(S) AND A NOTE
 OF ACKNOWLEDGEMENT TO MAINTAIN THE FIRE RATING OF THE
 BATHROOM WALL IF APPLICABLE.
  
  
 1A) PLEASE INDICATE ON THE FLOOR PLAN THE LOCATION AND
 DIMENSION OF THE REMOVAL AND REPLACEMENT OF THE PRPOSED
 FLOORING.
  
 PER NFPA 1
  
 1.7.12 PLANS AND SPECIFICATIONS.
  
 1.7.12.1 THE AHJ SHALL HAVE THE AUTHORITY TO REQUIRE
 PLANS AND SPECIFICATIONS TO ENSURE COMPLIANCE WITH
 APPLICABLE CODES AND STANDARDS.
  
 1.7.12.6 PLANS SHALL BE SUBMITTED TO THE AHJ PRIOR TO
 THE ALTERATION OF THE MEANS OF EGRESS OR FIRE
 PROTECTION SYSTEMS OF ANY EXISTING BUILDING.
  
 PLEASE PROVIDE DETAILS.
  
  
  
 2) THERE IS AN INDICATION WITHIN THE CONTRACT FOR THE
 INSTALLATION OF LAMINTATE OR VINYL FLOOR, BUT NO SPEC
 SHEET NOR PRODUCT NAME FOR THE ACTUAL PROPOSED
 FLOORING.
  
 LAMINATE OR VINYL FLOORING COULD HAVE DIFFERENT KINDS
 OF MANUFACTURING/TESTING FROM AROUND THE WORLD AND NOT
 ALL ARE TESTED AND MEETING LISTED AND NFPA STANDARDS.
  
 PER NFPA 101, CH 30
  
 30.3.3.3 INTERIOR FLOOR FINISH.
 30.3.3.1 GENERAL. INTERIOR FINISH SHALL BE IN
 ACCORDANCE WITH
 SECTION 10.2.
  
 10.2.7.2* FLOOR COVERINGS, OTHER THAN CARPET FOR WHICH
 10.2.2.2
 ESTABLISHES REQUIREMENTS FOR FIRE PERFORMANCE, SHALL
 HAVE A
 MINIMUM CRITICAL RADIANT FLUX OF 0.1 W/CM2.
  
 FOR THE OFFICIAL RECORD, PLEASE PROVIDE THE VINYL
 FLOORING NAME AND THE PRODUCT SPEC SHEETS OF THE
 PROPOSED FINISHED
 LAMINATE/VINYL FLOORING INDICATING THE FIRE BEHAVIOR
 RATING.
  
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  