| 2022-09-27 15:06:44 | 2ND BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | 2ND REQUEST: PROVIDE A FLASHING DETAIL PER FBC R703.4. | | | | | | 1. R703.4FLASHING. | | | APPROVED METAL FLASHING, VINYL FLASHING, SELF-ADHERED | | | MEMBRANES AND MECHANICALLY ATTACHED FLEXIBLE FLASHING | | | SHALL BE APPLIED SHINGLE-FASHION OR IN ACCORDANCE WITH | | | THE MANUFACTURERS INSTRUCTIONS. | | | 1.EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT | | | EXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND TO THE | | | SURFACE OF THE EXTERIOR WALL FINISH OR TO THE | | | WATER-RESISTIVE BARRIER COMPLYING WITH SECTION 703.2 | | | FOR SUBSEQUENT DRAINAGE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|