| Plan Review Notes For Permit 22061089 |
| Permit Number |
22061089 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2022-09-06 16:08:50 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC 107, THE PRODUCT APPROVAL IS NOT COMPLETE. FOR | | | INSTANCE SEE PAGES 3 AND 4. THE PAGES ARE PARTIAL | | | PAGES. | | | | | | 2. FBC R 703.4, SUBMIT A FLASHING DETAIL. | | | | | | | | | |
|