| Date |
Text |
| 2022-12-01 13:30:03 | FAILED |
| | |
| | 1) REPEAT COMMENT: A SURVEY IS REQUIRED. |
| | |
| | 2) REPEAT COMMENT: A PLAN WHICH INCLUDES THE BUILDING |
| | SETBACKS TO THE PROPERTY LINES IS REQUIRED. |
| | |
| | 3) ZONING WILL NOT ISSUE THE BUILDING PERMIT UNTIL THE |
| | REQUIRED TREE ALTERATION PERMIT HAS BY ISSUED BY THE |
| | PLANNING DIVISION. NOTE: NO TREES MAY BE |
| | REMOVED/RELOCATED PRIOR TO THE ISSUANCE OF THE TREE |
| | ALTERATION PERMIT. **** NO TREE ALTERATION PERMIT HAS |
| | BEEN SUBMITTED. **** |
| | |
| | 4) NO NEW PLANS WERE SUBMITTED TO ADDRESS THE ZONING |
| | COMMENTS MADE ON AUGUST 4, 2022. |
| | |
| | 5) REPEAT COMMENT: THE ARCHITECTURAL AND CIVIL SITE |
| | PLANS MUST MATCH THE LAYOUT ON THE PLANS SUBMITTED FOR |
| | THE PENDING MINOR PLANNED DEVELOPMENT AMENDMENT |
| | APPROVAL. ALL SUBMITTALS NEED TO INCLUDE CONSISTENT, |
| | CODE COMPLIANT PLANS. |
| | |
| | 6) THE FLOOR PLAN THAT IS INCLUDED WITH THE BUILDING |
| | PERMIT MATCHES THE FLOOR PLAN SUBMITTED WITH THE LATEST |
| | MINOR AMENDMENT SUBMITTAL; HOWEVER, THE SITE LAYOUT |
| | SURROUNDING THE BUILDING DOES NOT MATCH THE MINOR |
| | AMENDMENT SITE, LANDSCAPE, CIVIL AND ARCHITECTURAL PLAN |
| | LAYOUTS AND MUST BE CORRECTED WITH THIS BUILDING |
| | PERMIT. **** SUBMIT THE SAME PLAN LAYOUT SHOWN ON THE |
| | MINOR AMENDMENT FLOOR PLAN TO ADDRESS THIS COMMENT. |
| | **** |
| | |
| | 7) REPEAT COMMENT: THE ELEVATIONS DO NOT MATCH THE |
| | ELEVATIONS APPROVED AS PART OF THE ORIGINAL DEVELOPMENT |
| | ORDER OR THE PENDING MINOR PLANNED DEVELOPMENT |
| | AMENDMENT APPROVAL. ALL SUBMITTALS NEED TO INCLUDE |
| | CONSISTENT, CODE COMPLIANT PLANS. **** THE HIGH POINT |
| | OF THE FIN ELEMENT IS LISTED AS 26 FEET 8 INCHES ON THE |
| | MINOR AMENDMENT SUBMITTED ELEVATIONS AND 28 FEET ON THE |
| | PERMIT ELEVATIONS (EAST AND SOUTH). **** |
| | |
| | 8) THE TOTAL BUILDING AREA SHOWN ON SHEET T2 (3,856 SF) |
| | IS LESS SQUARE FOOTAGE THAN SHOWN ON THE ARCHITECTURAL |
| | SITE PLAN SUBMITTED TO THE PLANNING DIVISION AS PART OF |
| | THE MOST RECENT MINOR AMENDMENT RESUBMITTAL AS WELL AS |
| | THE ARCHITECTURAL SITE PLAN SHEET AS1 SUBMITTED WITH |
| | THE PERMIT (3,898 SF). THE PLANS AND INFORMATION SHALL |
| | MATCH. |
| | |
| | 9) REPEAT COMMENT: THE SIGNS REQUIRE SEPARATE |
| | PERMITTING AND SHALL BE REMOVED FROM THE ELEVATION |
| | DRAWINGS SUBMITTED WITH THIS PERMIT. PLEASE NOTE THAT |
| | THE BUILDING CONTAINS MORE SIGNAGE THAN IS PERMITTED BY |
| | THE CITY SIGN REGULATIONS. **** THE LATEST MINOR |
| | AMENDMENT PLANS ADDRESS THIS COMMENT **** |
| | |
| | 10) REPEAT COMMENT: PROVIDE VERIFICATION THAT THE |
| | PROPOSED ROOFTOP MECHANICAL EQUIPMENT, INCLUDING ANY |
| | RACK OR CURB, IS SCREENED FOR ITS FULL HEIGHT BY THE |
| | PROPOSED PARAPET WALL. **** THE LATEST MINOR AMENDMENT |
| | PLANS GRAPHICALLY SHOW THE MECHANICAL EQUIPMENT |
| | SCREENED; HOWEVER, FOR THE PERMIT, THE EQUIPEMENT |
| | HEIGHT (INCLUDING CURB), MUST BE INCLUDED TO VERIFY |
| | THAT THE PARAPETS PROVIDE SCREENING. |
| | |
| | 11) REPEAT COMMENT: PROVIDE VERIFICATION THAT THE TINT |
| | ON THE WINDOWS ALONG WEST EXECUTIVE CENTER DRIVE IS NOT |
| | SO DARK/REFLECTIVE THAT IT OBSTRUCTS THE VIEW INTO THE |
| | CAR WASH. |
| | |
| | 12) PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY |
| | FOR THE CAR WASH BUILDING THE PROPERTY OWNER MUST: |
| | |
| | A. RECORD A PUBLIC ACCESS EASEMENT, ACCEPTABLE TO THE |
| | CITY ATTORNEY'S OFFICE, FOR THE PLAZA ALONG WEST |
| | EXECUTIVE CENTER DRIVE. THE EASEMENT MAY OCCUR ON THE |
| | PLAT, WHICH IS ALSO REQUIRED PRIOR TO CO. |
| | B. GRANT THE REDEDICATED DRAINAGE EASEMENT TO THE CITY |
| | FOR THE EXISTING DRAINAGE PIPE ALONG THE SOUTH PROPERTY |
| | LINE. BY THIS RESOLUTION, THE CITY COMMISSION |
| | AUTHORIZES THE MAYOR TO EXECUTE ANY REQUIRED AGREEMENTS |
| | RELATED TO THE DRAINAGE EASEMENT TERMINATION AND |
| | REDEDICATION WITH THE PROPERTY OWNER. |
| | |
| | 13) SEPARATE PERMITS REQUIRED (SOME HAVE ALREADY BEEN |
| | APPLIED FOR): |
| | |
| | A. LANDSCAPE |
| | B. SIGNAGE |
| | C. PARKING LOT STRIPING |
| | D. HARDSCAPE, INCLUDING THE BICYCLE RACK, BENCHES, ETC. |
| | PLEASE REMEMBER THAT THE SEATING ALONG WEST EXECUTIVE |
| | CENTER DRIVE MUST MEET CRIME PREVENTION THROUGH |
| | ENVIRONMENTAL DESIGN (CPTED) STANDARDS. |
| | E. SITE LIGHTING NOTE: LIGHT POLES ARE SHOWN IN |
| | DIFFERENT LOCATIONS AND CONFLICTS ON THE SITE/LANDSCAPE |
| | PLANS, THE ARCHITECTURAL PLANS AND THE ELECTRICAL SITE |
| | PLAN. THE LIGHT POLE LOCATIONS ARE REQUIRED TO BE |
| | COORDINATED AMONG THE PLANS AS PART OF THE MINOR |
| | PLANNED DEVELOPMENT. THESE PLANS CAN THEN BE USED FOR |
| | THE SITE LIGHTING PERMIT. |
| | F. PAY STATIONS AND CANOPY |
| | G. DUMPSTER ENCLOSURE |
| | |
| | CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| | [email protected] |
| | |
| | |
| | |
| | |