| Date |
Text |
| 2022-07-20 09:24:13 | 1ST REVIEW FBC-2020 PLUMBING |
| | PERMIT- 22061055 |
| | 7/20/22 |
| | |
| | CODES IN EFFECT: |
| | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 |
| | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) SHEETS A-1.01 & A-2.01: CHURCHES ARE EXEMPT FROM |
| | TITLE III ADA SEC. 36.102(E) AND THE FLORIDA |
| | ACCESSIBILITY CODE- 2020, HOWEVER AN ADA COMPLIANT |
| | SINGLE USER TOILET ROOM IS SHOWN ON THE PLAN. PLEASE |
| | PROVIDE THE FOLLOWING DETAILS PER THE FBC ACC: |
| | A) THE DIMENSIONS OF THE CLEAR FLOOR SPACE FOR THE |
| | WATER CLOSET- SEC. 604.3. |
| | B) THE DIMENSIONS OF THE CLEAR FLOOR SPACE FOR THE |
| | LAVATORIES- SEC. 606.2. |
| | C) THE DIAMETER OF THE TURNING SPACE- SEC. 304.3. |
| | D) HEIGHT OF THE MIRROR MEASURED FROM THE FINISHED |
| | FLOOR TO THE REFLECTIVE SURFACES- SEC. 603.3. |
| | E) SHOW THE 36-INCH LONG REAR WALL GRAB BAR EXTENDING |
| | FROM THE CENTERLINE OF THE WATER CLOSET 12 INCHES |
| | MINIMUM ON ONE SIDE AND 24 INCHES MINIMUM ON THE OTHER |
| | SIDE- SEC. 604.5.2. |
| | F) CENTERLINE OF THE TOILET PAPER DISPENSER MEASURED |
| | FROM THE FRONT OF THE WATER CLOSET- SEC. AND FIGURE |
| | 604.7. |
| | G) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SEC. |
| | 606.2. |
| | |
| | 2) SHEETS A-1.01 & A-2.01: BASED ON COMMENT #1 ABOVE |
| | PLEASE CLARIFY THE DESIGN INTENTION FOR THE MEN'S AND |
| | WOMEN'S RESTROOMS. PLEASE NOTE IF COMPLIANCE WITH THE |
| | FBC ACC IS INTENDED THEN UNDER SEC. 213.2 FBC ACC THE |
| | CURRENT DESIGN IS NON-COMPLIANT. COMPLIANCE WOULD |
| | REQUIRE THE FOLLOWING CHANGES TO THE DESIGN PER SEC. |
| | 213.2- 213.3.5. |
| | A) A MINIMUM OF ONE ACCESSIBLE WATER CLOSET COMPARTMENT |
| | IN EACH ROOM- SEC. 604.8.1. |
| | B) A MINIMUM OF ONE ACCESSIBLE LAVATORY IN EACH ROOM- |
| | SEC. 606. |
| | C) A MINIMUM OF ONE ACCESSIBLE MIRROR IN EACH ROOM- |
| | SEC. 603.3. |
| | |
| | D) A CLEAR FLOOR SPACE DIAGRAM IS SHOWN AT THE URINAL |
| | WHICH IMPLIES AN ACCESSIBLE URINAL IS TO BE INSTALLED. |
| | PLEASE PROVIDE THE DIMENSIONS OF THE CLEAR FLOOR SPACE- |
| | SEC. 605.3, AND AN ELEVATION DETAIL SHOWING THE HEIGHT |
| | OF THE URINAL RIM- SEC. 605.2. |
| | |
| | 3) A-1.01: PROVIDE THE DEPTH AND WIDTH MEASUREMENTS OF |
| | THE TOILET COMPARTMENTS IN THE WOMEN'S RESTROOM |
| | MEASURED IN THE WATER CLOSET LOCATIONS- SEC. 405.3.1 |
| | FBC P. |
| | |
| | 4) P0.1, P1.1, & P3.1: IT APPEARS THE 1/2-INCH HW LINE |
| | TO THE LAVATORY IN THE UNISEX ADA TOILET ROOM WILL BE |
| | EXCEEDING THE MAXIMUM 2FT. LENGTH FROM THE HW SOURCE- |
| | SEC. C404.5.1 FBC EC. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |