2022-07-23 10:20:44****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. FS553, FBC BUILDING, THIS IS A CONDOMINIUM.
 ARCHITECT ON PAGE A101 STATES THIS IS R3, RESIDENTIAL
 CODE, TYPE V BUILDING TYPE. ARCHITECT ALSO STATES THAT
 GOVERINING CODE IS FBC RESIDENTIAL, THIS IS NOT CORRECT
 AS THIS IS NOT A ONE-OR-TWO-FAMILY DWELLING.
  
 AN ACCURATE REVIEW CANNOT BE DONE WITHOUT DETERMINING
 BUILDING TYPE AND OCCUPANCY CLASSIFICATION PER FBC
 BUILDING. THIS IS A CONDOMINIUM WHICH IS R2 OCCUPANCY.
 BUILDING TYPE V DOES NOT APPEAR TO BE CORRECT, PLEASE
 CONFIRM AND IF IT REMAINS TYPE V, INCLUDE A STATEMENT
 AS TO HOW THIS HAS BEEN DETERMINED, (SUCH AS BUILDING
 PLANS FROM ORIGINAL BUILDING PERMIT ISSUANCE).
  
 2. S101, ARCHITECT STATES WIND DESIGN CRITERIA AS
 ASCE10-05, EXPOSURE B, 170MPH. ASCE REFERENCE NOT
 CORRECT, EXPOSURE NOT CORRECT, NOTE THE PROXIMITY TO
 THE LAKE, PLEASE REVISE.
  
 3. FBC 107 CLARIFY SCOPE. APPLICATION IS FOR
 INSTALLATION OF PT LUMBER, PLAN AND SPECS SHOW FIBERON
 DECKING.
  
  
  
  