| Plan Review Notes For Permit 22060816 |
| Permit Number |
22060816 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2022-07-29 09:30:57 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. SUBMITTED MIAMI-DADE COUNTY NOA 18-0409.06 COVERS | | | MULTIPLE PRODUCTS & APPROVED ASSEMBLIES: SYSTEMS E(1) | | | THROUGH E(4). SELECT SYSTEM TO BE USED ON PAGE 4 OR | | | PAGE 5. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE | | | CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. | | | SECOND REQUEST. | | | 2. FBC B 107.2.1. REVISE SUBMITTED FASTENER DENSITY | | | CALCULATIONS PREPARED, SIGNED AND SEALED BY A FLORIDA | | | REGISTERED PROFESSIONAL ENGINEER; TO CORRECT ALL DATA. | | | DATA MUST REFERENCE MIAMI-DADE COUNTY NOA NO. | | | 20-0110.11 A FLAT ROOF SYSTEM NOT NOA NO. 20-0110.01 A | | | METAL PANEL ROOF SYSTEM. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | | |
|