| Date |
Text |
| 2022-06-27 11:15:41 | 1ST REVIEW FBC-2020 PLUMBING |
| | PERMIT- 22060780 |
| | 6/27/2022 |
| | |
| | CODES IN EFFECT: |
| | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| | 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) SHEET A100: THE FIXTURE CALCULATIONS SHALL BE |
| | CALCULATED FOR EACH OCCUPANCY SEPARATELY- SEC. AND |
| | TABLE 403.1 FBC P. BASED ON TABLE 403.1 FOOTNOTE(E), |
| | AND SEC. 410.2 SERVICE SINKS AND DRINKING FOUNTAINS ARE |
| | REQUIRED FIXTURES FOR UNITS A & B. PLEASE REVISE THE |
| | PLANS TO SHOW THE FIXTURE LOCATIONS AND PLUMBING PIPING |
| | DETAILS- SEC. 107.2.1 WPB. |
| | |
| | A) CONCERNING THE REQUIRED DRINKING FOUNTAINS, A |
| | MINIMUM OF TWO ARE REQUIRED PER SEC. 211.2 FBC ACC- ONE |
| | HI AND ONE LO FOR EACH UNIT. REFER TO SECTIONS 306, |
| | 307, AND 602 FBC ACC AND PROVIDE DRINKING FOUNTAIN |
| | INSTALLATION DETAILS AND ELEVATION VIEWS SHOWING KNEE |
| | AND TOE CLEARANCES, SPOUT HEIGHTS, AND SPOUT LOCATIONS. |
| | SHOW THE REQUIRED 30 X 48 IN. CLEAR FLOOR SPACE FOR A |
| | FORWARD WHEELCHAIR APPROACH TO THE FOUNTAIN- SECTION |
| | 602.2 FBC ACC, AND SHOW HOW THE LOCATIONS OF THE |
| | FOUNTAINS WILL BE IN COMPLIANCE WITH SECTION 307.2 |
| | PROTRUSION LIMITS. |
| | |
| | 2) A100 & P3: PLEASE IDENTIFY THE BATHROOMS AS EITHER |
| | MALE, FEMALE, OR UNISEX- SECS. 403.2 & 403.4 FBC P. |
| | |
| | 3) A100 & A600: THE GENERIC ACCESSIBLE STALL DETAILS ON |
| | A600 DO NOT REFLECT THE ACTUAL BATHROOM LAYOUTS PLANS |
| | FOR THE ACCESSIBLE BATHROOMS IN EACH UNIT. PROVIDE |
| | ENLARGED SITE-SPECIFIC ACCESSIBLE TOILET ROOM DRAWINGS |
| | FOR EACH UNIT SHOWING THE FOLLOWING LIST OF FBC ACC |
| | COMPLIANCES: |
| | A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE |
| | WATER CLOSETS- SEC. 604.3. |
| | B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE |
| | LAVATORIES- SEC. 606.2. |
| | C) TURNING SPACE DIAMETERS- SEC. 304.3. |
| | D) CENTERLINES OF THE WATER CLOSETS FROM THE SIDE |
| | WALLS- SEC. 604.2. |
| | E) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED |
| | FLOORS- SEC. 604.4. |
| | F) HEIGHTS OF THE LAVATORY SINK RIM OR COUNTER SURFACE |
| | FROM THE FINISHED FLOOR- SEC. 606.3. |
| | G) HEIGHTS OF THE MIRRORS FROM THE FINISHED FLOORS TO |
| | THE REFLECTIVE SURFACES- SEC. 603.3 |
| | H) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB |
| | BARS FOR THE WATER CLOSETS- SEC. 604.5 & 609.4, FIGURES |
| | 604. |
| | I) LOCATIONS OF THE WATER CLOSET FLUSH CONTROLS ? SEC. |
| | 604.6. |
| | J) CENTERLINES OF THE TOILET PAPER DISPENSERS MEASURED |
| | FROM THE FRONTS OF THE WATER CLOSETS- SEC. AND FIGURE |
| | 604.7. |
| | K) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SEC. |
| | 606.2. |
| | |
| | 4) A100 & A600: THE SHOWERS SHOWN IN BR2 & BR5 SHALL BE |
| | ACCESSIBLE IN ACCORDANCE WITH SEC. 213.3.6 FBC ACC. |
| | REVISE THE DRAWINGS TO PROVIDE THE FOLLOWING LIST OF |
| | FBC ACC COMPLIANCES: |
| | A) DIMENSIONS OF THE SHOWER- SEC. 608.2.1 |
| | B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE |
| | SHOWER- SEC. 608.2.1 |
| | C) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB |
| | BARS FOR THE ACCESSIBLE SHOWER- SEC. 608.3 AND 608.3.1 |
| | D) LOCATION OF CONTROL, FAUCET, AND SHOWER SPRAY IN THE |
| | SHOWER- SEC. 608.5.1. |
| | E) SHOWER SPRAY UNIT SPECIFICATIONS PER SEC. 608.6. |
| | F) LOCATION OF ACCESSIBLE SHOWER SEAT- SECS. 610.3 & |
| | 610.3.2. |
| | |
| | 5) A100 & A600: THE KITCHEN SINKS AND APPLIANCES SHOWN |
| | IN UNITS A & C SHALL BE ACCESSIBLE IN ACCORDANCE WITH |
| | SECS. 212.1 & 212.2 FBC ACC. PROVIDE ENLARGED DRAWINGS |
| | SHOWING THE CLEAR FLOOR SPACE DIAGRAMS AND DIMENSIONS |
| | FOR THE SINKS AND APPLIANCES- SEC. 606.2 & 804.1. |
| | |
| | 6) P-1: IWH-2 SHALL PROVIDE HOT WATER, NOT TEMPERED |
| | WATER TO THE KITCHEN SINKS AND DISHWASHERS- SEC. 607.1 |
| | FBC P. |
| | |
| | 7) P-1: PROVIDE A MEANS OF LIMITING THE HOT WATER |
| | DELIVERY TEMPERATURE FROM THE KITCHEN SINKS AND |
| | DISHWASHERS- SEC. 607.1.1 FBC P. |
| | |
| | 8) P-1 & P-3: THE 1/2-INCH HW PIPES SUPPLYING THE |
| | LAVATORIES HAVE EXCEEDED THEIR MAXIMUM ALLOWABLE 2FT. |
| | LENGTHS FROM THE IWH-1 SOURCES- TABLE C404.5.1 FBC EC. |
| | |
| | 9) P1: PROVIDE THE TYPE OF BACKFLOW PREVENTER TO BE |
| | INSTALLED- SEC. 608.3 FBC P AND SECS. C, D, & E WPB |
| | CROSS CONNECTION MANUAL. PLEASE NOTE A SEPARATE PERMIT |
| | IS REQUIRED FOR INSTALLATION OF THE DEVICE- SECS. 105.1 |
| | & 107.2.1 WPB. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |
| | |