| Plan Review Notes For Permit 22060665 |
| Permit Number |
22060665 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2022-08-02 13:17:24 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | WOOD FLOORS ARE PROPOSED OVER AN UNDERLAYMENT WHICH IS | | | NOT CLEAR. | | | | | | STC TEST FOR PROFLEX MSC 90 WAS SUBMITTED (QUARRY TILE, | | | 8" SLAB) - NOT OK | | | IIC TEST FOR PROFLEX SUPERSIM 90 (TILE, 6" SLAB) - TEST | | | OK | | | STC TEST FOR PROFLEX SUPERSIM 90 PARTIAL TEST SUBMITTED | | | - TEST OK (WE CAN PROVIDE COMPLETE TEST) | | | NO FLAME SPREAD SUBMITTED | | | | | | IT IS SUGGESTED THAT YOU EITHER CONTACT PROFLEX TO SEE | | | IF THEY HAVE A FLAME SPREAD TEST FOR SUPERSIM90 WITH A | | | COMBUSTIBLE FLOOR, OR CONSIDER PROFLEX LV200 AS PROFLEX | | | HAS RECOMMENDED THIS PRODUCT IN THE PAST AND WE HAVE | | | THE THREE TEST REPORTS ON FILE. IF YOU ELECT TO TAKE | | | THIS OPTION, PLEASE NOTE THAT I DO NOT TAKE INTO | | | ACCOUNT QUALITY, SUITABILITY, PRICE, ETC., SIMPLY CODE | | | COMPLIANCE AND AVAILABILITY OF THE TEST REPORTS. | | | | | | SEE PREVIOUS REVIEW FOR CODE REFERENCES. |
|