| Date |
Text |
| 2022-06-10 11:02:41 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE |
| | MARSHAL, WITH THE FOLLOWING COMMENTS: |
| | |
| | |
| | 1) THERE IS AN INDICATION ON THE DEMO PLAN TITLE BLOCK |
| | OF THE ADDRESS: 2600 S OCEAN BLVD, PALM BEACH. |
| | |
| | THE APPLICATION AND FLOOR PLAN INDICATE 2800 N FLALGER |
| | DR, WPB |
| | |
| | ENSURE THAT THE SUBMITTED FLOOR PLAN IS CORRECT TO THE |
| | ADDRESS WITHIN THE CITY OF WPBCH |
| | |
| | PLEASE CORRECT. |
| | |
| | |
| | |
| | |
| | 2) THERE ARE INDICATIONS OF NEW FLOORING; HOWEVER, |
| | THERE ARE FLOORING PRODUCT TYPE, UNDERLAYMENT NOR SPEC |
| | SHEETS THAT INDICATED THE REQUIRED FLAME RATING OF THE |
| | FINISH FLOORING |
| | |
| | PER NFPA 101, CH 30 |
| | |
| | 30.3.3.3 INTERIOR FLOOR FINISH. |
| | 30.3.3.1 GENERAL. INTERIOR FINISH SHALL BE IN |
| | ACCORDANCE WITH |
| | SECTION 10.2. |
| | |
| | 10.2.7.2* FLOOR COVERINGS, OTHER THAN CARPET FOR WHICH |
| | 10.2.2.2 |
| | ESTABLISHES REQUIREMENTS FOR FIRE PERFORMANCE, SHALL |
| | HAVE A |
| | MINIMUM CRITICAL RADIANT FLUX OF 0.1 W/CM2. |
| | |
| | FOR THE OFFICIAL RECORD, PLEASE PROVIDE THE FLOORING |
| | TYPE AND THE PRODUCT SPEC SHEETS OF THE PROPOSED |
| | FINISHED |
| | FLOORING, INCLUDING THE CARPET, INDICATING THE FIRE |
| | BEHAVIOR RATING. |
| | |
| | IF THE PROPOSED FLOORING IS, (OTHER THAN CARPET,) |
| | PORCELAIN OR CERAMIC TILE, NATURAL STONE TILE, CONCRETE |
| | TILES, SPEC SHEETS WOULD NOT BE REQUIRED. |
| | |
| | |
| | |
| | 3) THERE IS AN INDICATION OF A NEW SHOWER IN THE MASTER |
| | BATH. |
| | |
| | THAT PROPOSED WORK MAY INCLUDE REMOVING EXISTING SHOWER |
| | WALL TILE THAT MAY DAMAGE THE EXISTING FIRE RATED WALL |
| | BOARD. |
| | |
| | ENSURE FIRE RATED TENANT/CORRIDOR SEPARATION WALLS |
| | ARE MAINTAINED & REPAIRED IF DAMAGED. |
| | |
| | PLEASE PROVIDE A NOTE OF ACKNOWLEDGMENT ON THE PLAN |
| | SHEET. |
| | |
| | |
| | |
| | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET |
| | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE |
| | ABOVE. |
| | |
| | |
| | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE |
| | RE-SUBMITTAL OF THE ABOVE. |
| | |
| | |
| | PETER LEDUC |
| | FIRE MARSHAL |
| | 561-804-4709 |
| | [email protected] |
| | |