| Date |
Text |
| 2022-08-06 09:01:48 | PLAN REVIEW BUILDING |
| | |
| | CHRISTOPHER S. THROOP, C.B.O., CFM |
| | PLANS EXAMINER II PX3169/SFP306 |
| | BU1635 BN4338 |
| | ASFPM CFM US-21-11935 |
| | CITY OF WEST PALM BEACH |
| | (561) 805-6726 |
| | [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | NFPA 70 2017 EDITION NEC 2017 |
| | |
| | 1ST REVIEW |
| | |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | 1.PROVIDE THE FL PRODUCT APPROVALS OR MIAMI-DADE NOA |
| | FOR THE PROPOSED EXTERIOR DOOR (#12) TO BE INSTALLED. |
| | FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS, |
| | EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS. |
| | NOTE: NOA?S DO NOT HAVE COVER SHEETS. |
| | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | |
| | 2. IDENTIFY THE LOCATION OF THE TWO SHUTTERS ON THE |
| | FLOOR PLAN. |
| | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| | 107.2.5. |
| | |
| | SHUTTERS |
| | 3. PROVIDE A SCHEDULE OF OPENING PROTECTIVE DEVICES OR |
| | ASSEMBLIES. |
| | 1609.1.2 PROTECTION OF OPENINGS. |
| | IN WIND-BORNE DEBRIS REGIONS, GLAZED OPENINGS IN |
| | BUILDINGS SHALL BE IMPACT RESISTANT OR PROTECTED WITH |
| | AN IMPACT-RESISTANT COVERING MEETING THE REQUIREMENTS |
| | OF ANSI/DASMA 115 (FOR GARAGE DOORS AND ROLLING DOORS) |
| | OR TAS 201, 202 AND 203, AAMA 506, ASTM E1996 AND ASTM |
| | E1886 REFERENCED HEREIN, OR AN APPROVED |
| | IMPACT-RESISTANT STANDARD AS FOLLOWS: |
| | |
| | WHEN COMPLETING THE INSTALLATION SCHEDULE, PLEASE NOTE |
| | FACTORS THAT APPLY DEPENDING ON SUBSTRATE, EDGE |
| | DISTANCE AND FASTENER. FOR FASTENER, IF USING TAPCON, |
| | BE SPECIFIC AS TO WHICH TAPCON (TAPCON W/ADVANCED |
| | THREADFORM TECHNOLOGY REQUIRES A .9 FACTOR). |
| | |
| | NOTICE: I HAVE UPLOADED A COPY OF THE CITY'S SHUTTER |
| | SCHEDULE TO PROJECT DOX FOR YOUR REVIEW AND OR USE. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |