| 2022-11-21 14:57:33 | ADD MEZZANINE | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWING A1 - - HAND RAIL EXTENSIONS CANNOT TURN - | | | PLEASE SHOW THE STAIR HANDRAIL EXTENSIONS TO COMPLY | | | WITH - FBC 1014.6 HANDRAIL EXTENSIONS. | | | HANDRAILS SHALL RETURN TO A WALL, GUARD OR THE WALKING | | | SURFACE OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN | | | ADJACENT FLIGHT OF STAIRS OR RAMP RUN. WHERE HANDRAILS | | | ARE NOT CONTINUOUS BETWEEN FLIGHTS, THE HANDRAILS SHALL | | | EXTEND HORIZONTALLY NOT LESS THAN 12 INCHES (305 MM) | | | BEYOND THE TOP RISER AND CONTINUE TO SLOPE FOR THE | | | DEPTH OF ONE TREAD BEYOND THE BOTTOM RISER. THE | | | EXTENSIONS OF HANDRAILS SHALL BE IN THE SAME DIRECTION | | | OF THE FLIGHTS OF STAIRS AT STAIRWAYS AND THE RAMP RUNS | | | AT RAMPS. | | | | | | | | | | | | |
|