| Date |
Text |
| 2022-08-15 12:06:44 | 1ST REVIEW FBC-2020 PLUMBING |
| | PERMIT- 22060481 |
| | 8/15/2022 |
| | |
| | CODES IN EFFECT: |
| | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| | 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) LS1: PLEASE PROVIDE PLUMBING FIXTURE CALCULATIONS IN |
| | ACCORDANCE WITH TABLE 403.1 FBC P. PLEASE NOTE SEC. |
| | 410.3 FBC P. WHERE DRINKING FOUNTAINS ARE REQUIRED, NOT |
| | FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. |
| | ONE DRINKING FOUNTAIN SHALL COMPLY WITH THE |
| | REQUIREMENTS FOR PEOPLE WHO USE A WHEELCHAIR AND ONE |
| | DRINKING FOUNTAIN SHALL COMPLY WITH THE REQUIREMENTS |
| | FOR STANDING PERSONS. REFER TO SEC. 606.2 FOR REQUIRED |
| | ACCESSIBILITY DETAILS. |
| | |
| | 2) SHEET A2: PROVIDE THE DIMENSIONS OF THE CLEAR FLOOR |
| | SPACE DIAGRAMS SHOWN FOR THE WATER CLOSET, LAVATORY, |
| | AND LOUNGE SINKS- SECS. 604.3 & 606.2 FBC ACC. |
| | |
| | 3) SHEET A4 TOILET ELEVATIONS: PLEASE CORRECT THE |
| | DETAILS IN ACCORDANCE WITH THE FOLLOWING FBC |
| | ACCESSIBILITY CODE SECTIONS. |
| | A) SHOW THE WATER CLOSET GRAB BAR LENGTHS IN ACCORDANCE |
| | WITH SEC. 604.5 & FIGURES 604.5.1 & 604.5.2- THE SIDE |
| | WALL GRAB BAR SHALL BE 42 INCHES LONG MINIMUM, LOCATED |
| | 12 INCHES MAXIMUM FROM THE REAR WALL AND EXTENDING 54 |
| | INCHES MINIMUM FROM THE REAR WALL. THE REAR WALL GRAB |
| | BAR SHALL BE 36 INCHES LONG MINIMUM AND EXTEND FROM THE |
| | CENTERLINE OF THE WATER CLOSET 12 INCHES MINIMUM ON ONE |
| | SIDE AND 24 INCHES MINIMUM ON THE OTHER SIDE. |
| | B) SHOW THE LOCATION OF THE WATER CLOSET FLUSH CONTROL |
| | ON THE OPEN SIDE- SEC. 604.6. |
| | C) SHOW THE CENTERLINE OF THE TOILET PAPER DISPENSERS |
| | MEASURED FROM THE FRONT OF THE WATER CLOSETS- SEC. & |
| | FIGURE 604.7. |
| | D) SHOW THE KNEE AND TOE CLEARANCES FOR THE LAVATORIES |
| | IN ACCORDANCE WITH FIGURES- 306.2 & 306.3. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |