| Date |
Text |
| 2022-08-24 16:18:54 | BUILDING REVIEW COMMENTS: |
| | |
| | W.P.B. PERMIT: 22060459 |
| | REVIEWED: AUGUST 24, 2022 |
| | |
| | DYLAN BATTLES |
| | BUILDING PLANS EXAMINER PX4191 |
| | [email protected] |
| | 561-805-6718 |
| | |
| | FLORIDA BUILDING CODE,7TH EDITION (2020) |
| | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK |
| | BELOW) |
| | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ |
| | BUILDING-PERMIT-FORMS |
| | FBC[EXISTING] = FBC EXISTING BUILDING |
| | FBC[E] = FBC ENERGY CONSERVATION |
| | FBC[R] = FBC RESIDENTIAL |
| | |
| | 1. 311.3 FBC[R] FLOORS AND LANDINGS AT EXTERIOR DOORS. |
| | THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH |
| | EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL BE NOT |
| | LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A |
| | DIMENSION OF NOT LESS THAN 36 INCHES (914 MM) MEASURED |
| | IN THE DIRECTION OF TRAVEL. THE SLOPE AT EXTERIOR |
| | LANDINGS SHALL NOT EXCEED 1/4 UNIT VERTICAL IN 12 UNITS |
| | HORIZONTAL (2 PERCENT). |
| | - PROVIDE LANDING AT EXTERIOR SIDE OF DOORS IF GREATER |
| | THAN 2 RISERS PROVIDED. |
| | |
| | 2. 408.1 FBC[R] VENTILATION. THE UNDER-FLOOR SPACE |
| | BETWEEN THE BOTTOM OF THE FLOOR JOISTS AND THE EARTH |
| | UNDER ANY BUILDING (EXCEPT SPACE OCCUPIED BY A |
| | BASEMENT) SHALL HAVE VENTILATION OPENINGS THROUGH |
| | FOUNDATION WALLS OR EXTERIOR WALLS. |
| | - PLEASE PROVIDE THE AMOUNT OF EXISTING UNDER FLOOR |
| | VENTILATION AND SHOW WHERE ACCESS PANEL IS LOCATED. IT |
| | APPEARS THAT THE ADDITION MAY BLOCK SOME OF THE OLD |
| | VENTS SO A NEW CALCULATION SHOULD BE DONE FOR THE |
| | EXISTING AND IF ANY NEW CRAWL SPACE IS BEING DONE. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F |
| | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME |
| | [email protected] |
| | |
| | |
| | |