| Date |
Text |
| 2022-07-11 10:33:49 | JONATHAN BROOKS JR. |
| | BUILDING PLANS EXAMINER |
| | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM |
| | PHONE (561) 805-6656 |
| | EMAIL: [email protected] |
| | |
| | 1ST REVIEW: FBC 2020 7TH EDITION |
| | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| | FBC B = FBC BUILDING |
| | FBC R = FBC RESIDENTIAL |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT |
| | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. |
| | |
| | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT |
| | APPROVAL FL25621.02-R2 IS NOT RATED FOR USE IN ZONES 1, |
| | 2 OR 3 FOR STRUCTURES LOCATED IN EXPOSURE B, C OR D |
| | EXPOSURE AREA HAVE EITHER FLAT ROOF, GABLE/HIP ROOF |
| | WITH MAX SLOPE OF 12:12 WITH A MEAN ROOF HEIGHT 30 FEET |
| | OR LESS WIND SPEED 170 MPH. PROVIDE SIGNED AND SEALED |
| | ENGINEERING FOR USE OR SELECT A SYSTEM THAT MEETS THE |
| | ABOVE CRITERIA. PROJECT LOCATED IN EXPOSURE C CATEGORY |
| | AREA. |
| | 2. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL10450-R15 |
| | COVERS MULTIPLE PRODUCT TYPES; ROOF COVER OPTIONS; |
| | ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS, |
| | ALLOWABLE SUBSTRATES & ATTACHMENT LIMITATIONS. SELECT |
| | ALL APPLICABLE OPTIONS. ALL APPLICABLE DETAILS AND |
| | ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE PRODUCT |
| | APPROVAL DRAWINGS. |
| | 3. FBC B 107.3.4.1. SUBMITTED PRODUCT APPROVAL |
| | FL10450-R15 AND PRODUCT APPROVAL FL25621-R2 SHALL BE |
| | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN |
| | RESPONSIBLE CHARGE WHO SHALL REVIEW IT AND FORWARD IT |
| | TO THE BUILDING OFFICIAL WITH A NOTATION INDICATING |
| | THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN |
| | REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO THE |
| | DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL ITEMS |
| | SHALL NOT BE INSTALLED UNTIL THE DEFERRED SUBMITTAL |
| | DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. |
| | ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY |
| | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. |
| | |