2022-06-16 14:22:032ND REVIEW FBC-2020 PLUMBING
 PERMIT- 22051368
 6/16/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS SP-1 & 1: REFER TO SEC. 454.1.6.1.1 FBC B-
 CONCERNING THE PLUMBING FIXTURE CALCULATIONS PLEASE
 VERIFY WITH ADDITIONAL CALCULATIONS AND NOTES THAT THE
 POOL AND SPA DECK AREAS DO NOT EXCEED THREE TIMES THE
 POOL AND SPA SURFACE AREAS, AND THAT THE POOL BATHROOMS
 ARE FOR EXCLUSIVE USE OF OCCUPANTS OF THE POOL, SPA,
 AND DECK. THE CURRENT PLAN DOES NOT PROVIDE ENOUGH
 INFORMATION FOR APPROVAL- TABLE 454.1.6.1 & SECS.
 454.1.6.1.1, 454.1.8.1 FBC B.
 PLEASE NOTE THE EXCEPTION UNDER SEC. 454.1.6.1.1: IF
 THE BUILDING IS PROVIDING THE SANITARY FACILITIES FOR
 THE POOL, THEN THE FIXTURE REQUIREMENT FOR THE BUILDING
 SHALL BE DETERMINED AND IF IT EXCEEDS THE REQUIREMENT
 IN TABLE 454.1.6.1 THEN THE BUILDING REQUIREMENT SHALL
 REGULATE THE FIXTURE COUNT, OTHERWISE THE FIXTURE COUNT
 SHALL BE BASED ON THE REQUIREMENT FOR THE POOL. UNDER
 NO CIRCUMSTANCES SHALL THE FIXTURE COUNTS BE
 CUMULATIVE.
  
 2) SHEET 1: REFER TO SEC. 454.1.6.1.2 FBC B- BECAUSE
 THE DESIGNATED POOL BATHROOMS DO NOT HAVE DOORS THAT
 OPEN TO THE OUTSIDE, THE 114 FT. WALKING DISTANCE
 EXCEEDS THE MAXIMUM 50 FT. ALLOWED.
  
  
 3) SHEET 1: PLACE A NOTE AT THE POOL BATHROOMS
 INDICATING THE FLOORS SHALL BE CONSTRUCTED OF CONCRETE
 OR OTHER NON-ABSORBENT MATERIALS, AND SHALL HAVE A
 SMOOTH, SLIP RESISTANT FINISH- SEC. 454.1.6.1.3 FBC B.
  
 4) SHEETS 1: SHOW THE LOCATION OF THE REQUIRED HOSE
 BIBS WITH VACUUM BREAKERS EITHER IN, OR WITHIN 25 FT.
 OF THE MEN'S AND WOMEN'S POOL BATHROOMS- SEC.
 454.1.6.1.4 FBC B.
  
 5) SHEETS 4 & 5: THE ISOMETRIC DRAWING SHOWS WASTEWATER
 FROM THE FILTERS TO BE DRAINED INTO THE SANITARY SEWER
 WHICH IS PROHIBITED PER SEC. 90-126(5) WPB CODE OF
 ORDINANCES. PLEASE REVIEW THE FOLLOWING INFORMATION AND
 ADDRESS THE ISSUE.
  
 SWIMMING POOL WATER SHALL NOT BE DISCHARGED TO SANITARY
 SEWER WITHOUT PRIOR APPROVAL FROM THE PUBLIC UTILITIES
 DEPARTMENT.
 SWIMMING POOL WATER MAY BE DISCHARGED TO THE CITY
 STORMWATER SEWER ONLY IF THE WATER IS DECHLORINATED
 ACCORDING TO SECTION 90-205(1) OF THE CITY OF WEST PALM
 BEACH CODE OF ORDINANCES. SUBMIT THE MANUFACTURER?S
 SPECIFICATION FOR THE DICHLORINATION SYSTEM FOR REVIEW
 AND STAMPING BEFORE THE INSPECTION. AT THE TIME OF POOL
 WATER DISCHARGE, THE FOLLOWING WILL BE REQUIRED:
 * THE RECEIVING INLET MUST BE PROTECTED (FILTER CLOTH
 TO KEEP EXCESS SEDIMENTS FROM ROADWAY WASHING INTO THE
 INLET).
 * NO DISCHARGE HOSE CAN BE DIRECTLY INSERTED INTO THE
 INLET TO DISCHARGE EFFLUENT.
 * WHENEVER POSSIBLE, DISCHARGE EFFLUENT SHALL BE
 ALLOWED TO FILTER THROUGH GRASS AREA ON THE POOL OWNERS
 PROPERTY BEFORE DISCHARGING ON CITY PROPERTY.
 * DISCHARGE SHALL NOT FLOOD STREETS OR NEIGHBORING
 PROPERTY.
 * FOR TECHNICAL QUESTIONS, DON'T HESITATE TO CONTACT
 O&M SUPERINTENDENT STEPHON HARRIS AT [email protected] OR
 561-822-2168.
 * FOR STORMWATER DISCHARGE COMPLIANCE QUESTIONS, PLEASE
 CONTACT CHRIS JACKSON, ENVIRONMENTAL COMPLIANCE
 SPECIALIST III, PUBLIC UTILITIES DEPARTMENT, (561)
 822-2062 OR [email protected].
  
 6) SHEETS SP-1 & 1: SHOW THE LOCATION OF THE POTABLE
 WATER SUPPLY LINE FOR THE POOL AND THE REQUIRED RPZ
 BACKFLOW PREVENTER- SEC. 608.17.4.1 FBC P, & SECS C, D,
 & E WPB UTILITIES CROSS-CONNECTION MANUAL. PLEASE NOTE
 A SEPARATE PERMIT IS REQUIRED FOR INSTALLATION OF THE
 BACKFLOW PREVENTER- SEC. 105.1 & 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
  