| Date |
Text |
| 2022-07-29 15:20:00 | FAILED |
| | |
| | 1) THE SUBMITTED COMMUNICATION FACILITY PLACEMENT |
| | PERMIT - CITY RIGHTS-OF-WAY (21120225) MUST BE APPROVED |
| | PRIOR TO THIS PERMIT BEING APPROVED. THIS SUBMITTED |
| | PERMIT HAS BEEN UPDATED SINCE THE WCF ROW PERMIT. BOTH |
| | PLANS WILL NEED TO REFLECT THE SAME, CODE COMPLIANT |
| | CONDITIONS. THE COMMENTS BELOW ALSO APPLY TO THE WCF |
| | ROW PERMIT. |
| | |
| | 2) REPEAT COMMENT: THIS LOCATION IS WITHIN A HISTORIC |
| | DISTRICT. PLEASE PROVIDE A COPY OF THE STATE HISTORIC |
| | PRESERVATION OFFICE APPROVAL OF THIS LOCATION. |
| | |
| | 4) UPDATED COMMENT: PROVIDE A CROSS SECTION OF THE |
| | UNDERGROUND ELECTRIC WHICH VERIFIES THAT THERE ARE NO |
| | CONFLICTS WITH EXISTING UTILITIES. *** THE FULL LENGTH |
| | OF THE UNDERGROUND ELECTRIC RUN WAS NOT PROVIDED. |
| | |
| | 5) REPEAT COMMENT: THE PLANS SHOW THE COM LINES WITHIN |
| | 1-FOOT OF THE HANDHOLE AND INSTALLATION DIG. IN ORDER |
| | TO VERIFY THAT THE INSTALLATION WILL NOT INTERFERE WITH |
| | THE EXISTING FACILITIES, PROVIDE A PUBLIC UTILITY |
| | LETTER OF NO OBJECTION FROM THE COM PROVIDER(S), MOST |
| | LIKELY AT&T AND COMCAST. |
| | |
| | 6) THE NEW POLE LOCATION IS WITHIN FIVE FEET OF A GAS |
| | LINE. IN ORDER TO VERIFY THAT THE INSTALLATION WILL NOT |
| | INTERFERE WITH THE EXISTING FACILITIES, PROVIDE A |
| | PUBLIC UTILITY LETTER OF NO OBJECTION FROM THE FPU. |
| | |
| | 6) THE POLE STYLE AND HEIGHT MEET CITY REQUIREMENTS. |
| | THE POLE COLOR AT THIS LOCATION SHALL BE RAL/RAYCAP |
| | 7042 TRAFFIC GREY A. |
| | |
| | CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| | [email protected] |
| | |