2022-08-31 09:22:34NEW SFR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE A PROPOSED ELEVATION CERTIFICATE -
 FBC WPB 107.3.5.3
  
 2) PLEASE SHOW THE LOCATION OF THE DRAFT STOP WITHIN
 THE FLOOR TRUSSES - TYPE AND LOCATION - FBC R302.12
  
 3) PLEASE SHOW THE ROOF SLOPE DIMENSION - FBC R905.9.1
 SLOPE.
 BUILT-UP ROOFS SHALL HAVE A DESIGN SLOPE OF NOT LESS
 THAN ONE-FOURTH UNIT VERTICAL IN 12 UNITS HORIZONTAL
 (2-PERCENT SLOPE) FOR DRAINAGE,
  
 4) PLEASE PROVIDE THE SMART VENT CERTIFICATION - ICC
 EVALUATION OR MIAMI DADE NOA OR FLORIDA STATE PRODUCT
 APPROVAL.
  
 5) YOU WILL NEED TO APPLY FOR A SEPARATE PERMIT AND
 PROVIDE PLANS UNDER THE SEPARATE PERMIT FOR - POOL,
 SITE WALLS, POOL BARRIER, FENCES, EXISTING BUILDING
 DEMO.
  
  
  
  
  
  
  
  
  
  
  
  
  
  