| Date |
Text |
| 2022-06-17 14:26:43 | |
| | FAILED |
| | |
| | 1) THE SUBMITTED COMMUNICATION FACILITY PLACEMENT |
| | PERMIT - CITY RIGHTS-OF-WAY (21120295) MUST BE APPROVED |
| | PRIOR TO THIS PERMIT BEING APPROVED. THE PLANS ON THIS |
| | ELECTRIC PERMIT AND THE ONES ULTIMATELY RESUBMITTED |
| | WITH THE WCF ROW PERMIT NEED TO MATCH. THESE COMMENTS |
| | MIRROR THOSE PROVIDED FOR THE WCF ROW PERMIT. |
| | |
| | 2) THIS LOCATION IS WITHIN A HISTORIC DISTRICT. PLEASE |
| | PROVIDE A COPY OF THE STATE HISTORIC PRESERVATION |
| | OFFICE APPROVAL OF THIS LOCATION. |
| | |
| | 3) PLEASE CONSIDER MOVING THE POLE SOUTH A FEW FEET SO |
| | THAT IT IS CENTERED ON THE PROPERTY LINE OF THE PARCELS |
| | ON THE EAST SIDE OF THE SIDEWALK. |
| | |
| | 4) THE BORE PIT NOTES ON SHEET P-1 STATE THAT THE |
| | SIDEWALK WILL BE RESTORED; HOWEVER, THE PARKWAY WILL |
| | ALSO NEED RESTORATION. PLEASE UPDATE THE NOTATIONS |
| | ACCORDINGLY. |
| | |
| | 5) PROVIDE A CROSS SECTION OF THE UNDERGROUND ELECTRIC |
| | WHICH VERIFIES THAT THERE ARE NO CONFLICTS WITH |
| | EXISTING UTILITIES. |
| | |
| | 6) THE PLANS SHOW THE COM LINES WITHIN 2-FEET OF THE |
| | BORE PIT(S). IN ORDER TO VERIFY THAT THE INSTALLATION |
| | WILL NOT INTERFERE WITH THE EXISTING FACILITIES, |
| | PROVIDE A PUBLIC UTILITY LETTER OF NO OBJECTION FROM |
| | THE COM PROVIDER(S), MOST LIKELY AT&T OR COMCAST. |
| | |
| | 7) THE POLE STYLE AND HEIGHT MEET CITY REQUIREMENTS. |
| | THE POLE COLOR AT THIS LOCATION SHALL BE RAL/RAYCAP |
| | 7042 TRAFFIC GREY A. |
| | |
| | CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| | [email protected] |
| | |